48
DDJ-RZX
1
2
3
4
A
B
C
D
E
F
1
2
3
4
Each Channel TRIM,
HI, MID, LOW, COLOR
Crossfader
Each Channel Fader
18
18
24
24
30
30
36
36
23
23
29
29
35
35
41
41
48
48
19
19
25
25
31
31
37
37
20
20
26
26
32
32
38
38
21
21
27
27
33
33
39
39
22
22
28
28
34
34
40
40
23
23
29
29
35
35
41
41
48
48
22
22
18
18
19
19
20
20
21
21
24
24
25
25
26
26
27
27
30
30
31
31
32
32
33
33
36
36
37
37
38
38
39
39
28
28
34
34
40
40
[Details of test]
1
Select a fader/control to be tested by turning the rotary selector clockwise or counterclockwise.
At the beginning of this test mode, the control numbered 1 is selected.
As the rotary selector is turned by 1 click, the LED of the selected fader/control will light in the order indicated below.
Clockwise rotation: 1 2 3 4 . . . . . 54 55
Counterclockwise rotation: 55 54 53 . . . . . 2 1
2
Which control/fader is currently selected is indicated with lighting of the LED of the button corresponding to the selected
control/fader, as shown in the figure on the previous page.
The number same with the nunber on each element is the corresponding LED.
3
After the fader/control to be tested is selected, press the rotary selector to start monitoring the A/D conversion values.
The A/D conversion value monitored immediately after monitoring is started becomes the reference value.
• The A/D conversion values being monitored are raw data.
4
The A/D conversion values being monitored are indicated with the MASTER level indicator (L).
If no fluctuations are monitored with regard to the reference A/D value, all LEDs of the level indicator remain unlit.
In response to fluctuations with regard to the reference A/D conversion value, the corresponding LEDs light.
• Both greater and smaller A/D conversion values than the reference value remain indicated on the MASTER level indicator.
• Both greater and smaller maximum fluctuation values than the reference value remain indicated.
5
To reset the fluctuation values up until the present, press the rotary selector while monitoring A/D conversion values.
To reset the monitored A/D values, press the rotary selector. All LEDs will go dark. The A/D conversion value when the
rotary selector is pressed will become a new reference value.
Greater than the reference A/D conversion value by 7
Greater than the reference A/D conversion value by 6
Greater than the reference A/D conversion value by 5
Greater than the reference A/D conversion value by 4
Greater than the reference A/D conversion value by 3
Greater than the reference A/D conversion value by 2
Greater than the reference A/D conversion value by 1
Greater than the reference A/D conversion value by 1
Greater than the reference A/D conversion value by 2
Greater than the reference A/D conversion value by 3
Greater than the reference A/D conversion value by 4
Greater than the reference A/D conversion value by 5
Greater than the reference A/D conversion value by 6
Greater than the reference A/D conversion value by 7