86
DDJ-RZX
1
2
3
4
A
B
C
D
E
F
1
2
3
4
8.3 ITEMS FOR WHICH USER SETTINGS ARE AVAILABLE
This unit is provided with user settable items, as shown below.
If the corresponding part or board Assy is replaced for repair, change the user resettable settings to those noted on the Check
Sheet before starting repair. If resetting is not possible, when returning the repaired product, be sure to tell the customer that
the Utility settings have been cleared and will have to be reset, as required.
Each of the above items can be set in Utilities screen.
Press the [WAKE UP (UTILITY)] button for over 1 second. The utilities screen appears on a center display of this unit.
IC2006
(MAIN Assy)
Utility setting
Operations to be switched in response to running /not running of rekordbox /
Forced operations to be generally expected from the MIDI controller
MIDI controller setting
Booth output attenuator
level setting
OFF (Microphone audio NOT to be output from the BOOTH OUT connector) /
0 dB
/ −3 dB / −6 dB / −9 dB / −12 dB / −15 dB / −18 dB
Output setting of microphone
to booth monitor
Enables the low cut filter of microphone sound
/
Disables the low cut filter of microphone sound
Operation setting of
microphone sound low cut filter
Peak limiter enabled
/ Peak limiter disabled
Peak limiter setting
2 (Brightly lit)
/ 1 (dimly lit) / unlit
Brightness setting of jog ring
MONO /
STEREO
Monaural / stereo setting of
master output
Limiter ON (enabled) /
Limiter OFF (Disabled)
Limiter setting of microphone
audio added to master output
Limiter ON (enabled) /
Limiter OFF (Disabled)
Limiter setting of microphone
audio added to booth output
MONO /
STEREO
Monaural / stereo setting of
booth output
3
/ 1 (Dark) to 5 (Bright)
Unit display section brightness
setting
Left touch panel /
Center touch panel
/ Right touch panel
Touch panel calibration setting
0.5 mm /
1.0 mm
/ 3.7 mm
Cut lag setting of crossfader
0 dB
(no attenuation) / −3 dB / −6 dB / −9 dB / −12 dB
Setting of the auto standby
function
Auto standby function enabled
/ Auto standby function disabled
Master output attenuator
level setting
0 dB
(no attenuation) / −3 dB / −6 dB / −9 dB / −12 dB
Demo mode and screen saver
function setting
Demo mode to be started after 10 minutes of nooperation
/
to be started after 5 minutes of nooperation /
to be started after 1 minute of nooperation / Screen saver function disabled
Demo mode disabled
Setting of talk
over function
Mode setting
Advanced • Talk over mode
/ Normal • Talk over mode
Level setting
−6 dB / −12 dB / −
18 dB
/ −24 dB
Item for Which User's
Setting is Available
Part Name
Content to
be Stored
Setting Value
(The factory default settings are indicated in bold.)