Technical Data
Standard
Options
Function
electronic pressure switch with display; based on ceramics sensor
Life Cycle
at least 100 mio. switch cycles
Pressure Ranges (relative or absolute)
0 - 1 bar; 0 - 1,6 bar; 0 - 2,5 bar; 0 - 4 bar;
0 - 6 bar; 0 - 10 bar; 0 - 16 bar; 0 - 25 bar
Vacuum Ranges (relative)
-1...0 bar; -1...+1 bar; -1...+5 bar; -1...+9 bar; -1...+15 bar; -1...+24 bar
Overpressure Safety (short time)
> 2,5x FS
on request
Burst Pressure
> 3,0x FS
on request
Vaccum Safety
-1 bar
Material Enclosure
Aluminium
on request
Material Pressure Inlet (wetted)
Aluminium
Stainless Steel 1.4404 (AISI
316L)
Material Sensor (wetted)
Al
2
O
3
Material Seal (wetted)
FKM
(NBR and FKM fro sub-base
mouting)
on request
Permissible Media Temperature
-20...+85°C
Permissible Ambient Temperature
-20...+85°C
Output Signals
either 1x PNP, 2x PNP or 1x PNP with analogue output 4 - 20 mA
Switch Accuracy, Repeatability
< 0,5% FS
Accuracy Analogue Output
< 0,5% FS
Longterm Stability (DIN EN 60770)
± 0,5% FS
Switch Point / Reset Point
adjustable > 0,5% FS - 100% FS / adjustable > 0,5% FS from
switch point
Switching Function
adjustable, normally open, normally closed, hysteresis-mode,
window-mode
Response Time
< 10ms
Switching Current DC
max. 0,5 A
Max. Load Resistance
600 Ω
Display
OLED
Switch State Indicator
1 LED per channel (yellow)
Menu Navigation
oriented to VDMA standard sheet 24574-1 (with addition plain text
menu)
Menu Language
adjustable - English, French, German, Italian, Spanish
Supply
24 VDC (15 - 32 VDC)
on request
Power Consumption
< 50 mA
Process Connection
either sub-base mounting or 1/4“ female thread
Electrical Connection
M12x1 plug (5-pin)
Weight
approx. 0,3 kg
Protection (EN 60529)
IP65 (with installed counter-plug)
Shock Resistance (XYZ-direction)
30g, xyz, DIN EN 60068-2-27 (11ms)
Vibration Resistance (XYZ-direction)
5g (10….150Hz), xyz DIN EN 60068-2-6
Electromagnetic Compatibility
EMC-Directive 2004/108/EC,
EN 61326-1:2013, EN 61326-2-3:2013;
EN 61000-6-2:2005; EN 61000-6-4:2007 + A1:2011
Further Functions
zero-point adjustment, adjustable switching and re-set delay,
changable units, adjustable display power off, rotatable display
indication, password protection
Further Options
cleaned for O
2
service