31
pinnacolopizzaovens.com
BURNER WILL NOT LIGHT
• Is the LPG tank valve turned off?
Turn the LPG tank on.
• Is there gas in the LPG gas fuel tank?
Check the gas level.
• Is the igniter working?
Check that the igniter battery is properly installed or check to
see if the battery needs to be replaced. Check to see if the Burner
will match-light. See “Manually Lighting the Main Burner” in the
“Outdoor Burner Use” section. Check for loose wire connections to
the igniter.
Check to see if debris is blocking the electrodes.
If a spark occurs anywhere but the igniter tip, replace the igniter.
BURNER FLAME WILL NOT STAY LIT
• Is the gas supply fully turned on?
Check that the LPG tank valve is fully open
• Is the gas supply in the LPG tank low?
Check the gas level
• Is the burner properly installed and in good condition?
Check that the burner is installed properly. Check for defects
in the burner.
FLAME IS NOISY, LOW OR ERRATIC
• Is the gas supply fully turned on?
Check that the LPG tank valve is fully open.
• Is the gas supply in the LPG tank low?
Check the gas level
• Does the burner appear low?
Check and clean the burner ports if clogged or dirty.
• Is the gas supply hose bent or kinked?
Straighten the gas supply hose
• Is the burner flame mostly yellow or orange?
Burner may be in an area that is too windy, or not receiving enough
air. Check the burner air inlets for obstructions.
LOW HEAT
LPG TANK:
For outdoor ovens using a LPG gas, slowly open the
tank valve.
NOTE: If flow limiting device activates, your
burner may not light. If your burner does light,
the flames will be low and will not heat properly.
1. Turn tank valve and all control knobs off and wait 30 seconds.
2. After shutting off the tank, very slowly open the tank valve and
wait 5 seconds before lighting.
3. Light the burners one at a time.
MAINTENANCE FREQUENCY:
According to the frequency of use and habits, before using this
product, you must first check whether there are cracks in the gas
line, whether the ignition needle and the ignition needle thread
are damaged, and the normal maintenance cycle should
be checked once a week.
TROUBLESHOOTING MAINTENANCE
Pinnacola_Gas_PizzaOven_Manual_BLK.indd 31
Pinnacola_Gas_PizzaOven_Manual_BLK.indd 31
2021-07-02 3:24 PM
2021-07-02 3:24 PM