Propane Forced Air Heater User’s Manual
NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR
WHILE CONNECTED TO A POWER SOURCE
9
STORAGE / MAINTENANCE
Always disconnect the heater from the LP cylin-
der before putting the heater into storage. If for
any reason the heater is to be stored indoors,
the tank MUST be disconnected from the LP
cylinder, and the cylinder stored outdoors in a
well-ventilated area, out of the reach of children,
and in accordance with the Standard for Storage
and Handling of Petroleum Gases, ANSI/NFPA
58 - latest edition and Natural Gas and Propane
Installation Code, CSA B149.1. The plastic valve
plug or valve cover supplied with the cylinder
must be re-installed on the valve to protect the
fitting from damage.
NOTE: Installation and repair of this heater
should be done by a qualified service person.
ALWAYS
be sure to follow proper maintenance
procedures. This should include cleaning the
inside of the heater once a month and checking
the spark gap at least once a heating season.
Re-gap the terminals to 0.160” (4mm)
Never store an LP
cylinder inside of
a building or near
any other gas or oil burning appliances.
DANGER
WIRING DIAGRAMS
40-GFA
60V-GFA / 125V-GFA / 150V-GFA
Figure 6