![Pinnacle Remington REM-125V-GFA-B User'S Manual & Operating Instructions Download Page 4](http://html1.mh-extra.com/html/pinnacle/remington-rem-125v-gfa-b/remington-rem-125v-gfa-b_users-manual-and-operating-instructions_1557403004.webp)
© 2018 Pinnacle Climate Technologies, Inc.
Propane Forced Air Heater User’s Manual
NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR
WHILE CONNECTED TO A POWER SOURCE
4
ALWAYS install the heater so that it is not directly
exposed to water spray, rain, dripping water, or wind.
– Use heater in accordance with all local codes. In
the absence of local codes, refer to The National
Fuel Code, ANSI A223.1/NFPA 54.
– This heater is shipped from the factory for use
with propane (LP) gas only. Do not convert to
any other gas. Installation must conform to local
codes, or in their absence, with the standard for
the Storage and Handling of Liquefied Petroleum
Gases ANSI/NFPA 58 and the Natural Gas and
Propane Installation Code CSA B149.1.
– Gas supply connections should be checked by
using a 50/50 soap and water solution. Never use
a flame to check for gas leaks.
– Locate LP cylinder at least 6 ft. (183 cm) (10
ft./305 cm in Canada) from the heater, and do not
direct heater discharge towards the LP cylinder
unless it is at least 20 feet (610 cm) from the
heater.
– Use only the regulator and hose assembly
provided with this heater. Inspect the regulator/
hose assembly prior to each use of the heater. If
there is excessive abrasion or wear, or if the hose
is cut, replace it with the proper assembly shown
in the parts list, prior to using the heater.
Manifold, Minimum, and Maximum Inlet Pressure
40-GFA
60V-GFA 125V-GFA 150V-GFA
Man.
11" / 279
mm W.C.
11" / 279
mm W.C.
8.3" / 211
mm W.C.
8" / 203
mm W.C.
Min.
5 PSI (34.5 kPa)
Max.
Bottle Pressure
For use with pro-
pane (LP) gas only.
WARNING
Electrical Ground-
ing Instructions:
This appliance is
equipped with a three-prong (grounding)
plug for your protection against shock haz-
ard and should be plugged directly into a
properly grounded three-prong receptacle.
WARNING
RISK OF ELEC-
TRIC SHOCK!
WARNING
SAFETY INFORMATION (CONT.)
The hose assembly
shall be pro tected
from traffic, build-
ing material and contact with hot surfaces
both during use and while in storage.
WARNING
X
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
RISK OF FIRE! DO NOT POSITION HEATER IN A DOWNWARD
ANGLE. ALWAYS LOCATE HEATER ON A STABLE AND LEVEL SUR-
FACE (SEE FIGURE 1)!
Figure 1
WARNING
UNPACKING
1. Remove all packing items applied to heater for
shipment. Keep plastic cover caps attached to
inlet connector and hose / regulator assembly for
storage.
2. Remove all items from carton
3. Check all items for shipping damage. If the
heater is damaged, promptly inform dealer
where you purchased the heater.
The Propane (LP)
gas pressure
regulator and hose
assembly supplied with the heater must be
used without alteration.
CAUTION