background image

5

NEVER LEAVE HEATER UNATTENDED WHILE BURNING 

OR WHILE CONNECTED TO A POWER SOURCE

© 2021 Pinnacle Climate Technologies, Inc. 

Kerosene Forced Air Heater User’s Manual 

ASSEMBLY INSTRUCTIONS (140T-KFA / 175T-KFA / 215T-KFA)

1.  Tilt  the  heater  tank  backward  and  attach  the 

wheel support frame by inserting it into the but-

ton spring clips at the back of the bottom support 

frame.

2.  Attach the axle supports by inserting them into 

the button spring clips at the front of the bottom 

support frame.

3.  Insert the axle through the holes in the axle sup-

ports.

4.  Slide the spacers onto the axle.
5.  Slide the wheels onto the axle and secure with the 

axle nuts.

6.  Attach  the  rear  handle  by  inserting  the  handle 

into the button spring clips at the rear of the top 

support frame.

7.  Check all parts to ensure they are secure before 

operating the heater.

SPECIFICATIONS

Model #

45-KFA

80T-KFA

140T-KFA

175T-KFA

215T-KFA

Rating: Btu/Hr / kW

45,000 / 13.2

80,000 / 23.4

140,000 / 41

175,000 / 51.3

215,000 / 63

Fuel Consumption: Gal/Hr / L/Hr

0.35 / 1.32

0.63 / 2.38

1.10 / 4.16

1.34 / 5.07

1.63 / 6.17

Fuel Tank Capacity: Gallons / Liters

5 / 19

5 / 19

10 / 38

13 / 49

13 / 49

Pump Pressure: psi / BAR

3.0 / 0.21

4.2 / 0.29

6.6 / 0.46

7.5 / 0.52

9.0 / 0.62

Volts: AC/Hz

120VAC / 60Hz

120VAC / 60Hz

120VAC / 60Hz

120VAC / 60Hz

120VAC / 60Hz

Amps

1.4

1.5

2.4

2.7

2.8

Phase

Single

Single

Single

Single

Single

Specifications subject to change without notice.

FEATURES

 

Figure 1

Axle

Axle Nut

Spacer

Tire

Axle Support

Upper Shell

Power 

Cord

Drain Bolt

Fuel Tank

Pressure 

Gauge

Fan Guard

Rear Handle

Digital Temperature 

Display

Lamp

Thermostat 

Knob

Fuel Cap

Fuel Gauge

Lower Shell

Hot Air 

Outlet

Hot Air Outlet

Upper Shell

Handle

Extension Cord Wrap

Fan Guard

Pressure Gauge

Fuel Gauge

Fuel Cap

Power Cord

Fuel Tank

Power/Reset Switch

Thermostat Knob 

(80T KFA Only)

Lamp

Lower Shell

Summary of Contents for REMINGTON REM-140T-KFA-B

Page 1: ...N THIS HEATER IS SUITABLE FOR OUTDOOR USE AND INDOOR USE ONLY IN WELL VENTILATED AREAS INDOOR USE PERMITTED ONLY FOR THE TEMPORARY HEATING OF ADEQUATELY VENTILATED BUILDINGS OR STRUCTURES UNDER CONSTR...

Page 2: ...ED DO NOT START THE HEATER WHEN THE CHAMBER IS HOT WARNING WARNING FIRE BURN INHALATION AND EXPLOSION HAZARD Keep combustibles such as building materials paper or cardboard a safe distance away from t...

Page 3: ...D COMBUSTIBLES AWAY FROM HEATER WARNING The products described in this manual are kerosene direct fired forced air heaters Kerosene forced air heaters are primarily intended for use for temporary heat...

Page 4: ...ging materials from the shipping carton Note Save the box and packaging materials for future storage Shown With Optional Cord Wraps Cord Wraps Optional Carry Handle 1 10 mm Screws 2 15 mm Screws 2 WHA...

Page 5: ...secure before operating the heater SPECIFICATIONS Model 45 KFA 80T KFA 140T KFA 175T KFA 215T KFA Rating Btu Hr kW 45 000 13 2 80 000 23 4 140 000 41 175 000 51 3 215 000 63 Fuel Consumption Gal Hr L...

Page 6: ...ight or near a source of heat NEVER use kerosene that has been stored from one season to the next Kerosene deteriorates over time OLD KEROSENE WILL NOT BURN PROPERLY IN THIS HEATER NOTE Kerosene shoul...

Page 7: ...o not have a room temperature display feature The room temperature display will indicate the following When the temperature is less than 0 F the display says LO When the temperature is more that 99 F...

Page 8: ...re starting the heater FUEL FILTER The fuel filter should be cleaned at least twice per heating season Clean the filter by rinsing it in clean K 1 Kerosene Contaminated fuel could make cleaning the fu...

Page 9: ...rating turn adjusting screw clockwise to increase counter clockwise to decrease pressure Correct pump pressure is as follows Model Number Pump Pressure 45 KFA 3 0 PSI 0 21 BAR 80T KFA 4 2 PSI 0 29 BAR...

Page 10: ...2021 Pinnacle Climate Technologies Inc Kerosene Forced Air Heater User s Manual WIRING DIAGRAMS 80T KFA 140T KFA 175T KFA 190T KFA 215T KFA Models 140T 175T 190T 215T KFA have a digital display 80T K...

Page 11: ...mproper spacing with rotor 1 Fill tank with fresh kerosene 2 Adjust pump pressure 3 Clean replace spark plug 4 Clean replace fuel filter 5 Clean replace nozzle 6 Rinse fuel tank with clean fresh keros...

Page 12: ...A POWER SOURCE 2021 Pinnacle Climate Technologies Inc Kerosene Forced Air Heater User s Manual EXPLODED VIEW 45 KFA 80T KFA Only 140T KFA 215T KFA Only 13 10 12 8 11 9 29 25 3 15 2 4 6 1 7 21 23 16 17...

Page 13: ...dy 70 020 0101 70 020 0101 70 020 0101 70 020 0401 70 020 0401 18 Rotor Kit 70 022 0100 70 022 0100 70 022 0100 70 022 0200 70 022 0200 19 End Pump Cover 70 020 0102 70 020 0102 70 020 0102 70 020 010...

Page 14: ...aid If Pinnacle Climate Technologies Inc finds the item to be in normal operating condition or not defective the item will be returned freight collect This Limited Warranty is in lieu of all other exp...

Page 15: ...e ces instructions devraient utiliser ou entretenir cette chaufferette Pour obtenir plus de renseignements manuel d utilisation tiquettes etc contacter Pinnacle Climate Technologies au 800 641 6996 DA...

Page 16: ...A CHAUFFER ETTE LORSQUE LA CHAMBRE DE COMBUSTION EST CHAUDE RISQUE D INCENDIE DE BR LURE D INHALATION ET D EXPLOSION Garder les mat riaux combustibles tels que mat riaux de construction papier ou cart...

Page 17: ...emanuelsontdes chaufferettes feudirectet airpuls aliment esau k ros ne Leschaufferettes airforc auk ros nesont principalementdestin esauchauffagetemporairedes b timentsencoursdeconstruction demodifica...

Page 18: ...carton Remarque Conserver la bo te et les mat riaux d emballage pour y ranger ult rieurement la chaufferette Illustr avec enrouleurs de cordon en option Enrouleurs de cordon en option Poign e 1 Vis d...

Page 19: ...5T KFA 215T KFA SP CIFICATIONS Mod les n 45 KFA 80T KFA 140T KFA 175T KFA 215T KFA Classement Btu h kWh 45 000 13 2 80 000 23 4 140 000 41 175 000 51 3 215 000 63 Consommation de carburant L h 1 32 2...

Page 20: ...t d une source de chaleur NE JAMAIS utiliser du k ros ne entrepos la saison pr c dente pour la saison suivante Le k ros ne se d t riore avec le temps LE VIEUX K ROS NE NE BR LE PAS CORRECTEMENT DANS C...

Page 21: ...ce L afficheur de temp rature ambiante affiche LO Bas lorsque la temp rature ambiante est inf rieure 18 C HI lev e lorsque la temp rature ambiante est sup rieure 37 C Entre 18 C et 37 C l afficheur in...

Page 22: ...e carburant doit tre nettoy au moins deux fois par saison de chauffage Nettoyer le filtre en le rin ant dans du k ros ne K 1 propre Nettoyer le filtre imm diatement en cas de carburant contamin FILTRE...

Page 23: ...fonctionne tourner la vis de r glage de la pompe dans le sens horaire pour augmenter la pression et dans le sens antihoraire pour diminuer la pression Pression correcte de la pompe Num ro de mod le Pr...

Page 24: ...rique 80T KFA 140T KFA 175T KFA 190T KFA NOIR NOIR CELLULE PHOTO LECTRIQUE NOIR NOIR CAPTEUR DE TEMP RATURE AMBIANTE NOIR NOIR FICHE LECTRIQUE JAUNE BLANC VERT LIMITEUR INTERRUPTEUR D ALIMENTATION 120...

Page 25: ...Jeu incorrect du rotor 1 Remplir le r servoir de k ros ne neuf 2 V rifier la pression de la pompe 3 Nettoyer remplacer la bougie 4 Nettoyer remplacer le filtre carburant 5 Nettoyer remplacer la buse...

Page 26: ...E UNE SOURCE DE COMBUSTIBLE 2021 Pinnacle Climate Technologies Inc Manuel de la chaufferette air forc au k ros ne VUE CLAT E 45 KFA 80T KFA seulement 140T KFA 215T KFA seulement 13 10 12 8 11 9 29 25...

Page 27: ...70 021 0510 70 021 0520 70 021 0520 17 Corps de la pompe 70 020 0101 70 020 0101 70 020 0101 70 020 0401 70 020 0401 18 Trousse de rotor 70 022 0100 70 022 0100 70 022 0100 70 022 0200 70 022 0200 19...

Page 28: ...Pinnacle Climate Technologies Inc r parera ou remplacera et retournera l article en port pay Si Pinnacle Climate Technologies Inc d termine que l article est dans un tat d utilisation normale ou n es...

Reviews: