background image

3

NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR 

WHILE CONNECTED TO A POWER SOURCE

© 2020 Pinnacle Climate Technologies, Inc. 

Kerosene Forced Air Heater User’s Manual 

SAFETY INFORMATION (CONT.)

ALWAYS use only the electrical power (voltage and 

frequency) specified on the model plate of the heater.

ALWAYS use only three-prong, grounded outlet and 

extension cord. 
ALWAYS use only 14 AWG or better extension cord.
ALWAYS unplug the heater when not in use.  
ALWAYS install the heater so that it is not directly 

exposed to water spray, rain, dripping water, or wind.

NEVER use fuels such as gasoline, benzine, paint 

thinners or other oil compounds in this heater.
NEVER refill the heater’s fuel tank while the heater 

is operating or still hot. This heater is EXTREMELY 

HOT while in operation. 
NEVER block air inlet (rear) or air outlet (front).
NEVER use duct work in front or rear of heater.
NEVER move or handle heater while still hot.

NEVER transport heater with fuel in tank.
NEVER use with an external fuel tank.

Keep all combustible materials away from this heater. 

Minimum Clearance From Combustibles

45-190T-KFA

215T-KFA

Top

4 ft. (122 cm)

4 ft. (122 cm)

Sides

4 ft. (122 cm)

4 ft. (122 cm)

Front

8 ft. (244 cm)

10 ft. (305 cm)

ALWAYS locate heater on a stable and level surface. 
If your heater is equipped with a thermostat, once it 

is plugged in, it can start at anytime in accordance 

with the thermostat setting. 

RISK OF BURNS, 

FIRE AND 

EXPLOSION!

RISK OF ELECTRIC 

SHOCK!

WARNING

WARNING

CAUTION! HOT 

WHILE IN OP-

ERATION. DO 

NOT TOUCH. KEEP CHILDREN, ANIMALS, 

CLOTHING AND COMBUSTIBLES AWAY 

FROM HEATER. 

WARNING

The products described in this manual are 
kerosene direct-fired, forced air heaters. Kerosene 
forced air heaters are primarily intended for use for 
temporary heating of buildings under construction, 
alteration or repair. Direct-fired means that all 
of the combustion products of the heater enter 
the heated space. This appliance is rated at 98% 
combustion efficiency, but does produce small 
amounts of carbon monoxide.

Carbon monoxide is toxic. Humans can tolerate 
only small amounts of carbon monoxide and so 
precautions should be taken to provide proper 
ventilation. Failure to provide proper ventilation 
in accordance with the instructions in this 
manual can result in death.People with breathing 
problems should consult a physician before 
using this heater. Early signs of carbon monoxide 
poisoning resemble the flu. Symptoms of improper 
ventilation/carbon monoxide poisoning are:

Headache 

• 

Dizziness 

 Nausea 

• 

Dry Mouth 

Sore 

Throat 

 Burning of Nose and Eyes

If you experience any of these symptoms: 
GET FRESH AIR AT ONCE! 

Have your heater 

serviced and check for proper ventilation. Some 

people are more affected by carbon monoxide 

than others. These include: pregnant women, those 

with heart or lung problems, anemia or those under 

the influence of alcohol or at high altitudes. 
FOR OUTDOOR USE. INDOOR USE PERMITTED 
ONLY FOR: The temporary heating of adequately 
ventilated buildings or structures under 
construction, alteration or repair. Provide at 
least a three square foot (2,800 sq cm) opening 
of outside air for every 100,000 Btu/Hr (29 kW) 
heater rating. Refer to “Ventilation” on page 6 for 
further instructions.

RISK OF INDOOR 

AIR POLLUTION!

WARNING

CARBON 

MONOXIDE 

POISONING MAY 

LEAD TO DEATH!

DANGER

Summary of Contents for Master MH-140T-KFA

Page 1: ...R IS SUITABLE FOR OUTDOOR USE AND INDOOR USE ONLY IN WELL VENTILATED AREAS INDOOR USE PERMITTED ONLY FOR THE TEMPORARY HEATING OF ADEQUATELY VENTILATED BUILDINGS OR STRUCTURES UNDER CONSTRUCTION ALTER...

Page 2: ...NOT START THE HEATER WHEN THE CHAMBER IS HOT WARNING WARNING FIRE BURN INHALATION AND EXPLOSION HAZARD Keep com bustibles such as building materials paper or cardboard a safe dis tance away from the...

Page 3: ...D COMBUSTIBLES AWAY FROM HEATER WARNING The products described in this manual are kerosene direct fired forced air heaters Kerosene forced air heaters are primarily intended for use for temporary heat...

Page 4: ...ging materials from the shipping carton Note Save the box and packaging materials for future storage Shown With Optional Cord Wraps Cord Wraps Optional Carry Handle 1 10 mm Screws 2 15 mm Screws 2 WHA...

Page 5: ...Extension Cord Wrap Fan Guard Pressure Gauge Fuel Gauge Fuel Cap Power Cord Fuel Tank Power Reset Switch Thermostat Knob 80T KFA Only Lamp Lower Shell Upper Shell Power Cord Drain Bolt Fuel Tank Pres...

Page 6: ...ght or near a source of heat NEVER use kerosene that has been stored from one season to the next Kerosene deteriorates over time OLD KEROSENE WILL NOT BURN PROPERLY IN THIS HEATER NOTE Kerosene should...

Page 7: ...o not have a room temperature display feature The room temperature display will indicate the following When the temperature is less than 0 F the display says LO When the temperature is more that 99 F...

Page 8: ...re starting the heater FUEL FILTER The fuel filter should be cleaned at least twice per heating season Clean the filter by rinsing it in clean K 1 Kerosene Contaminated fuel could make cleaning the fu...

Page 9: ...E While heater is operating turn adjusting screw clockwise to increase counter clockwise to decrease pressure Correct pump pressure is as follows Model Number Pump Pressure 45 KFA 3 0 PSI 0 21 BAR 80T...

Page 10: ...TO A POWER SOURCE 2020 Pinnacle Climate Technologies Inc Kerosene Forced Air Heater User s Manual WIRING DIAGRAMS 80T KFA 140T KFA 175T KFA 190T KFA 215T KFA Models 140T 175T 190T 215T KFA have a digi...

Page 11: ...mproper spacing with rotor 1 Fill tank with fresh kerosene 2 Adjust pump pressure 3 Clean replace spark plug 4 Clean replace fuel filter 5 Clean replace nozzle 6 Rinse fuel tank with clean fresh keros...

Page 12: ...A POWER SOURCE 2020 Pinnacle Climate Technologies Inc Kerosene Forced Air Heater User s Manual 13 10 12 8 11 9 29 25 3 15 2 4 6 1 7 21 23 16 17 18 20 30 19 14 39 32 33 34 28 27 5 31 30 24 26 36 35 37...

Page 13: ...70 020 0401 70 020 0401 18 Rotor Kit 70 022 0100 70 022 0100 70 022 0100 70 022 0200 70 022 0200 19 End Pump Cover 70 020 0102 70 020 0102 70 020 0102 70 020 0102 70 020 0102 20 Filter Kit 70 054 010...

Page 14: ...eight pre paid If Pinnacle Climate Technologies Inc finds the item to be in normal operating condition or not defective the item will be returned freight collect This Limited Warranty is in lieu of al...

Page 15: ...ARA USO ESTERIOR Y USO INTERIOR PERO S LO EN REAS BIEN VENTILADAS EL USO EN INTERIORES S LO SE PERMITE PARA CALEFACCI N TEMPORAL DE EDIFICIOS ADECUADAMENTE VENTILADOS O ESTRUCTURAS EN CONSTRUCCI N MOD...

Page 16: ...P65Warnings ca gov ADVERTENCIA NO ENCIENDA EL CALENTADOR CUANDO LA C MARA EST CALIENTE ADVERTENCIA PELIGRO DE INCENDIO QUEMADURAS INHALACI N Y EXPLOSI N Mantenga los combustibles como materiales de c...

Page 17: ...seno Los calentadores de aire forzado de queroseno est n hechos expresamente para calefacci n temporal de edificios en construcci n modificaci n o reparaci n Fuego directo significa que todos los prod...

Page 18: ...de env o Nota Guarde la caja y los materiales de empaque para cuando guarde la unidad posteriormente Ilustrado con el cable opcional Enrolladores Enrolladores de cable Opcional Asa 1 Tornillos de 10 m...

Page 19: ...parador Llanta Soporte del eje ESPECIFICACIONES N de modelo 45 KFA 80T KFA 140T KFA 190T KFA 215T KFA Capacidad nominal BTU H kWh 45 000 13 2 80 000 23 4 140 000 41 190 000 55 7 215 000 63 Consumo de...

Page 20: ...una temporada a la siguiente El queroseno se deteriora con el tiempo EL QUEROSENO VIEJO NO SE QUEMAR ADECUADAMENTE EN ESTE CALENTADOR NOTA El queroseno debe almacenarse nicamente en un contenedor azu...

Page 21: ...ra es inferior a 0 F 18 C la pantalla mostrar LO Baja Cuando la temperatura es superior a 99 F 37 C la pantalla mostrar HI Alta Entre 0 F 18 C y 99 F 37 C la pantalla mostrar la temperatura real Apaga...

Page 22: ...RO DE COMBUSTIBLE El filtro de combustible debe limpiarse al menos dos veces por cada temporada de calefacci n Enjuague el filtro con queroseno K 1 limpio El combustible contaminado podr a hacer que s...

Page 23: ...alentador est funcionando gire la v lvula de seguridad hacia la derecha para aumentar la presi n o hacia la izquierda para disminuirla A continuaci n se muestra la presi n correcta de la bomba Modelo...

Page 24: ...ITOR 10UF 250 VCA CA 120 V 60 Hz INTERRUPTOR DE ENCENDIDO CONTROL DE L MITE AMARILLO FUSIBLE 8 A 125 VCA VERDE TIERRA BLANCO PCI DE CONTROL LUZ LED TERMOSTATO CONTROL DE TEMP FOTOC LULA SENSOR DE AMBI...

Page 25: ...resi n de la bomba 3 Limpie o reemplace la buj a 4 Limpie o reemplace el filtro de combustible 5 Limpie o reemplace la boquilla 6 Enjuague el interior del tanque con queroseno nuevo y limpio 7 Inspecc...

Page 26: ...NTE DE ALIMENTACI N 2020 Pinnacle Climate Technologies Inc Manual del usuario del calentador de aire forzado de queroseno VISTA DETALLADA S lo 45 KFA 80T KFA S lo 140T KFA 215T KFA 13 10 12 8 11 9 29...

Page 27: ...0 020 0101 70 020 0101 70 020 0401 70 020 0401 18 Juego de rotor 70 022 0100 70 022 0100 70 022 0100 70 022 0200 70 022 0200 19 Cubierta de la bomba 70 020 0102 70 020 0102 70 020 0102 70 020 0102 70...

Page 28: ...Pinnacle Climate Technologies Inc descubre que el art culo est en condiciones normales de funcionamiento o que no est defectuoso se devolver el art culo con el flete por cobrar Esta Garant a Limitada...