Pinnacle Climate Technologies Master MH-140T-KFA User'S Manual & Operating Instructions Download Page 28

14

NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ 

ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE 

DE ALIMENTACIÓN

© 2020, Pinnacle Climate Technologies, Inc. 

Manual del usuario del calentador de aire forzado  

de queroseno 

GARANTÍA LIMITADA (GARANTÍA LIMITADA DEL MOTOR DE 5 AÑOS)

Pinnacle Climate Technologies, Inc.

 garantiza este 

calentador únicamente al comprador minorista original, 

como libre de defectos en materiales y mano de obra 

por un periodo de un (1) año a partir de la fecha de la 

compra inicial. Este producto debe instalarse, mantenerse 

y usarse correctamente de acuerdo con las instrucciones 

suministradas.

Pinnacle Climate Technologies, Inc.

 requiere un 

comprobante razonable de su fecha de compra a un 

minorista o distribuidor autorizado.  Por lo tanto, debe 

conservar su recibo de venta, factura o cheque cancelado 

de la compra original.  Esta Garantía Limitada se limitará 

a la reparación o reemplazo de piezas que resulten 

defectuosas en uso y servicio normales dentro del periodo 

de la garantía, lo cual determinará Pinnacle Climate 
Technologies, Inc.

 a su discreción razonable.

Esta garantía no se aplica a los productos comprados para 

uso en alquiler.

Esta Garantía Limitada no cubre fallas o dificultades de 

funcionamiento debidas a uso y desgaste normales, 

accidente, abuso, uso inadecuado, modificación, mala 

aplicación, instalación inadecuada o mantenimiento y 

servicio inadecuados por usted o un tercero.  Tampoco 

cubre el daño por falta de mantenimiento normal y de 

rutina al calentador, el daño en el envío, daño relacionado 

con insectos, aves o animales de cualquier tipo y daños 

causados por condiciones climáticas.

Además, la Garantía Limitada no cubre daños en el acabado 

como rayones, abolladuras, decoloración, corrosión u otros 

daños causados por el clima después de la compra.

Todos los costos de transporte para devolver un producto 

o piezas dañadas serán responsabilidad del comprador. 

Previa recepción del artículo dañado, Pinnacle Climate 
Technologies, Inc.

 examinará el artículo y determinará 

si está defectuoso. Pinnacle Climate Technologies, Inc. 

reparará o reemplazará y devolverá el artículo, con el flete 

pagado por adelantado.

Si Pinnacle Climate Technologies, Inc. descubre que el 

artículo está en condiciones normales de funcionamiento o 

que no está defectuoso, se devolverá el artículo con el flete 

por cobrar. Esta Garantía Limitada reemplaza a todas las 

demás garantías expresas. Pinnacle Climate Technologies, 
Inc.

 desiste de todas las garantías de productos que se 

compren a vendedores que no sean distribuidores o 

concesionarios autorizados.

DESPUÉS DE QUE VENZA EL PERIODO DE UN (1) 

AÑO DE LA GARANTÍA EXPRESA, Pinnacle Climate 
Technologies, Inc.

 DESISTE DE TODAS Y CADA 

UNA DE LAS GARANTÍAS IMPLÍCITAS, INCLUIDAS, 

SIN LIMITACIONES, LAS GARANTÍAS IMPLÍCITAS DE 

COMERCIALIZACIÓN Y APTITUD PARA UNA APLICACIÓN 

EN PARTICULAR. ADEMÁS, Pinnacle Climate Technologies, 
Inc.

 NO TENDRÁ RESPONSABILIDAD ALGUNA ANTE EL 

COMPRADOR O CUALQUIER TERCERO POR DAÑOS 

ESPECIALES, INDIRECTOS, PUNITIVOS, INCIDENTALES 

O EMERGENTES. Pinnacle Climate Technologies, Inc. 

no asume responsabilidad alguna por cualquier defecto 

ocasionado por terceros. Esta Garantía Limitada otorga al 

comprador derechos legales específicos; el comprador 

podría tener otros derechos, dependiendo de dónde viva. 

Algunos estados no permiten la exclusión o limitación de 

daños especiales, incidentales o emergentes o limitaciones 

a la duración de una garantía, así que la exclusión y las 

limitaciones anteriores podrían no aplicarse en su caso.

Pinnacle Climate Technologies, Inc.

 no autoriza a persona 

o compañía alguna a asumir por ella alguna otra obligación 

o responsabilidad relacionada con la venta, instalación, 

uso, retiro, devolución o reemplazo de su equipo, y ninguna 

declaración de tal índole es vinculante para Pinnacle 
Climate Technologies, Inc.

Asegúrese siempre de especificar el número de modelo 

y número de serie cuando haga alguna reclamación a 
Pinnacle Climate Technologies, Inc.

 Para su comodidad, 

use el espacio de abajo para indicar esta información.

N.° de modelo: ________________________________

N.° de serie: __________________________________

Fecha de compra: _____________________________

Cómo localizar su número de serie:

El número de serie lo puede encontrar en una etiqueta blanca en el lado derecho de la cubierta de su 

calentador. Es una serie de 9 dígitos. Por ejemplo: 131234956. Tenga su número de serie a la mano antes de 

llamar al servicio al cliente al 800-641-6996.

 

XX-X-XXX

XXX

 

Etiqueta con el 

número de serie

Summary of Contents for Master MH-140T-KFA

Page 1: ...R IS SUITABLE FOR OUTDOOR USE AND INDOOR USE ONLY IN WELL VENTILATED AREAS INDOOR USE PERMITTED ONLY FOR THE TEMPORARY HEATING OF ADEQUATELY VENTILATED BUILDINGS OR STRUCTURES UNDER CONSTRUCTION ALTER...

Page 2: ...NOT START THE HEATER WHEN THE CHAMBER IS HOT WARNING WARNING FIRE BURN INHALATION AND EXPLOSION HAZARD Keep com bustibles such as building materials paper or cardboard a safe dis tance away from the...

Page 3: ...D COMBUSTIBLES AWAY FROM HEATER WARNING The products described in this manual are kerosene direct fired forced air heaters Kerosene forced air heaters are primarily intended for use for temporary heat...

Page 4: ...ging materials from the shipping carton Note Save the box and packaging materials for future storage Shown With Optional Cord Wraps Cord Wraps Optional Carry Handle 1 10 mm Screws 2 15 mm Screws 2 WHA...

Page 5: ...Extension Cord Wrap Fan Guard Pressure Gauge Fuel Gauge Fuel Cap Power Cord Fuel Tank Power Reset Switch Thermostat Knob 80T KFA Only Lamp Lower Shell Upper Shell Power Cord Drain Bolt Fuel Tank Pres...

Page 6: ...ght or near a source of heat NEVER use kerosene that has been stored from one season to the next Kerosene deteriorates over time OLD KEROSENE WILL NOT BURN PROPERLY IN THIS HEATER NOTE Kerosene should...

Page 7: ...o not have a room temperature display feature The room temperature display will indicate the following When the temperature is less than 0 F the display says LO When the temperature is more that 99 F...

Page 8: ...re starting the heater FUEL FILTER The fuel filter should be cleaned at least twice per heating season Clean the filter by rinsing it in clean K 1 Kerosene Contaminated fuel could make cleaning the fu...

Page 9: ...E While heater is operating turn adjusting screw clockwise to increase counter clockwise to decrease pressure Correct pump pressure is as follows Model Number Pump Pressure 45 KFA 3 0 PSI 0 21 BAR 80T...

Page 10: ...TO A POWER SOURCE 2020 Pinnacle Climate Technologies Inc Kerosene Forced Air Heater User s Manual WIRING DIAGRAMS 80T KFA 140T KFA 175T KFA 190T KFA 215T KFA Models 140T 175T 190T 215T KFA have a digi...

Page 11: ...mproper spacing with rotor 1 Fill tank with fresh kerosene 2 Adjust pump pressure 3 Clean replace spark plug 4 Clean replace fuel filter 5 Clean replace nozzle 6 Rinse fuel tank with clean fresh keros...

Page 12: ...A POWER SOURCE 2020 Pinnacle Climate Technologies Inc Kerosene Forced Air Heater User s Manual 13 10 12 8 11 9 29 25 3 15 2 4 6 1 7 21 23 16 17 18 20 30 19 14 39 32 33 34 28 27 5 31 30 24 26 36 35 37...

Page 13: ...70 020 0401 70 020 0401 18 Rotor Kit 70 022 0100 70 022 0100 70 022 0100 70 022 0200 70 022 0200 19 End Pump Cover 70 020 0102 70 020 0102 70 020 0102 70 020 0102 70 020 0102 20 Filter Kit 70 054 010...

Page 14: ...eight pre paid If Pinnacle Climate Technologies Inc finds the item to be in normal operating condition or not defective the item will be returned freight collect This Limited Warranty is in lieu of al...

Page 15: ...ARA USO ESTERIOR Y USO INTERIOR PERO S LO EN REAS BIEN VENTILADAS EL USO EN INTERIORES S LO SE PERMITE PARA CALEFACCI N TEMPORAL DE EDIFICIOS ADECUADAMENTE VENTILADOS O ESTRUCTURAS EN CONSTRUCCI N MOD...

Page 16: ...P65Warnings ca gov ADVERTENCIA NO ENCIENDA EL CALENTADOR CUANDO LA C MARA EST CALIENTE ADVERTENCIA PELIGRO DE INCENDIO QUEMADURAS INHALACI N Y EXPLOSI N Mantenga los combustibles como materiales de c...

Page 17: ...seno Los calentadores de aire forzado de queroseno est n hechos expresamente para calefacci n temporal de edificios en construcci n modificaci n o reparaci n Fuego directo significa que todos los prod...

Page 18: ...de env o Nota Guarde la caja y los materiales de empaque para cuando guarde la unidad posteriormente Ilustrado con el cable opcional Enrolladores Enrolladores de cable Opcional Asa 1 Tornillos de 10 m...

Page 19: ...parador Llanta Soporte del eje ESPECIFICACIONES N de modelo 45 KFA 80T KFA 140T KFA 190T KFA 215T KFA Capacidad nominal BTU H kWh 45 000 13 2 80 000 23 4 140 000 41 190 000 55 7 215 000 63 Consumo de...

Page 20: ...una temporada a la siguiente El queroseno se deteriora con el tiempo EL QUEROSENO VIEJO NO SE QUEMAR ADECUADAMENTE EN ESTE CALENTADOR NOTA El queroseno debe almacenarse nicamente en un contenedor azu...

Page 21: ...ra es inferior a 0 F 18 C la pantalla mostrar LO Baja Cuando la temperatura es superior a 99 F 37 C la pantalla mostrar HI Alta Entre 0 F 18 C y 99 F 37 C la pantalla mostrar la temperatura real Apaga...

Page 22: ...RO DE COMBUSTIBLE El filtro de combustible debe limpiarse al menos dos veces por cada temporada de calefacci n Enjuague el filtro con queroseno K 1 limpio El combustible contaminado podr a hacer que s...

Page 23: ...alentador est funcionando gire la v lvula de seguridad hacia la derecha para aumentar la presi n o hacia la izquierda para disminuirla A continuaci n se muestra la presi n correcta de la bomba Modelo...

Page 24: ...ITOR 10UF 250 VCA CA 120 V 60 Hz INTERRUPTOR DE ENCENDIDO CONTROL DE L MITE AMARILLO FUSIBLE 8 A 125 VCA VERDE TIERRA BLANCO PCI DE CONTROL LUZ LED TERMOSTATO CONTROL DE TEMP FOTOC LULA SENSOR DE AMBI...

Page 25: ...resi n de la bomba 3 Limpie o reemplace la buj a 4 Limpie o reemplace el filtro de combustible 5 Limpie o reemplace la boquilla 6 Enjuague el interior del tanque con queroseno nuevo y limpio 7 Inspecc...

Page 26: ...NTE DE ALIMENTACI N 2020 Pinnacle Climate Technologies Inc Manual del usuario del calentador de aire forzado de queroseno VISTA DETALLADA S lo 45 KFA 80T KFA S lo 140T KFA 215T KFA 13 10 12 8 11 9 29...

Page 27: ...0 020 0101 70 020 0101 70 020 0401 70 020 0401 18 Juego de rotor 70 022 0100 70 022 0100 70 022 0100 70 022 0200 70 022 0200 19 Cubierta de la bomba 70 020 0102 70 020 0102 70 020 0102 70 020 0102 70...