TROUBLESHOOTING GUIDE

Problem

Possible Cause

Solution

Heater Ignites, but main PCB shuts 
off after a short period of time. 
Lamp flickers and LED display shows 
“E1”.

1.  Incorrect pump pressure.
2.  Dirty input, output or lint filter.
3.  Dirty fuel filter.
4.  Nozzle is dirty.
5.  Photocell lens is dirty.
6.  Photocell not installed properly.
7.  Photocell is defective.
8.  Improper electrical connection 

between main PCB and photocell.

9.  Improper location of thermister sensor 

(does not apply to 45-KFA model)

10.  Improper electrical connection within 

the temperature limit switch

1.  Adjust pump pressure.
2.  Clean / replace air or lint filter.
3.  Clean / replace fuel filter.
4.  Clean / replace Nozzle.
5.  Clean / replace photocell.
6.  Adjust photocell position
7.  Replace photocell
8.  Check wiring connections  

(see wiring diagrams on page 10).

9.  Check thermister placement

10.  Replace temperature limit switch

Heater will not operate or motor 
runs for a short time.
Lamp flickers and LED display shows 
“E1”.

1.  No kerosene in the fuel tank.
2.  Incorrect pump pressure.
3.  Corroded spark plug or incorrect 

plug gap.

4.  Dirty fuel filter.
5.  Dirty nozzle.
6.  Moisture in fuel tank. 

7.  Improper electrical connection 

between transformer and circuit 
board.

8.  Ignitor wire not connected to spark 

plug.

9.  Defective ignitor. 
10.  Improper spacing with rotor

1.  Fill tank with fresh kerosene.
2.  Adjust pump pressure.
3.  Clean / replace spark plug. 

4.  Clean / replace fuel filter. 
5.  Clean / replace nozzle.
6.  Rinse fuel tank with clean, fresh 

kerosene.

7.  Inspect all electrical connections 

(see wiring diagrams on page 10). 

8.  Re-attach ignitor wire to spark plug. 

9.  Replace ignitor.  
10.  Adjust rotor

Fan does not operate when heater 
is plugged in and power switch is 
in the “ON” position. The lamp is 
flickering or and LED display shows 
“E1” or “E2”.

1.  Thermostat is set too low (does not 

apply to 45-KFA model).

2.  Broken electrical connection 

between main PCB and motor. 

1.  Rotate thermostat to a higher setting
2.  Inspect all electrical connections 

(see wiring diagrams on page 10).

Lamp is flickering and LED display 
shows “E3”.

1.  Thermostat switch has failed.

1.  Replace thermostat switch (see 

Wiring diagrams on page 10).

Poor combustion and / or excess 
soot production. 

1.  Dirty input, output or lint filter.
2.  Dirty fuel filter.
3.  Poor quality of fuel.
4.  PSI is too high or too low. 
5.  Dirty nozzle

1.  Clean / replace air or lint filter.
2.  Clean / replace fuel filter.
3.  Flush fuel tank and refuel heater.
4.  Use proper pressure. 
5.  Clean / replace nozzle

Heater does not turn on and the 
lamp is not lit.

1.  Temperature limit sensor has 

overheated. 

2.  No electrical power.

3.  Fuse is blown.
4.  Improper electrical connection 

between temperature limit sensor 
and circuit board. 

1.  Push power switch to “OFF and 

allow heater to cool for 10 minutes. 
Restart heater. 

2.  Check power cords for proper 

connection and test the power 
supply.

3.  Check / replace the fuse.
4.  Inspect all electrical connections 

(see wiring diagrams on page 10).

Summary of Contents for Master MH-140T-KFA

Page 1: ...R IS SUITABLE FOR OUTDOOR USE AND INDOOR USE ONLY IN WELL VENTILATED AREAS INDOOR USE PERMITTED ONLY FOR THE TEMPORARY HEATING OF ADEQUATELY VENTILATED BUILDINGS OR STRUCTURES UNDER CONSTRUCTION ALTER...

Page 2: ...NOT START THE HEATER WHEN THE CHAMBER IS HOT WARNING WARNING FIRE BURN INHALATION AND EXPLOSION HAZARD Keep com bustibles such as building materials paper or cardboard a safe dis tance away from the...

Page 3: ...D COMBUSTIBLES AWAY FROM HEATER WARNING The products described in this manual are kerosene direct fired forced air heaters Kerosene forced air heaters are primarily intended for use for temporary heat...

Page 4: ...ging materials from the shipping carton Note Save the box and packaging materials for future storage Shown With Optional Cord Wraps Cord Wraps Optional Carry Handle 1 10 mm Screws 2 15 mm Screws 2 WHA...

Page 5: ...Extension Cord Wrap Fan Guard Pressure Gauge Fuel Gauge Fuel Cap Power Cord Fuel Tank Power Reset Switch Thermostat Knob 80T KFA Only Lamp Lower Shell Upper Shell Power Cord Drain Bolt Fuel Tank Pres...

Page 6: ...ght or near a source of heat NEVER use kerosene that has been stored from one season to the next Kerosene deteriorates over time OLD KEROSENE WILL NOT BURN PROPERLY IN THIS HEATER NOTE Kerosene should...

Page 7: ...o not have a room temperature display feature The room temperature display will indicate the following When the temperature is less than 0 F the display says LO When the temperature is more that 99 F...

Page 8: ...re starting the heater FUEL FILTER The fuel filter should be cleaned at least twice per heating season Clean the filter by rinsing it in clean K 1 Kerosene Contaminated fuel could make cleaning the fu...

Page 9: ...E While heater is operating turn adjusting screw clockwise to increase counter clockwise to decrease pressure Correct pump pressure is as follows Model Number Pump Pressure 45 KFA 3 0 PSI 0 21 BAR 80T...

Page 10: ...TO A POWER SOURCE 2020 Pinnacle Climate Technologies Inc Kerosene Forced Air Heater User s Manual WIRING DIAGRAMS 80T KFA 140T KFA 175T KFA 190T KFA 215T KFA Models 140T 175T 190T 215T KFA have a digi...

Page 11: ...mproper spacing with rotor 1 Fill tank with fresh kerosene 2 Adjust pump pressure 3 Clean replace spark plug 4 Clean replace fuel filter 5 Clean replace nozzle 6 Rinse fuel tank with clean fresh keros...

Page 12: ...A POWER SOURCE 2020 Pinnacle Climate Technologies Inc Kerosene Forced Air Heater User s Manual 13 10 12 8 11 9 29 25 3 15 2 4 6 1 7 21 23 16 17 18 20 30 19 14 39 32 33 34 28 27 5 31 30 24 26 36 35 37...

Page 13: ...70 020 0401 70 020 0401 18 Rotor Kit 70 022 0100 70 022 0100 70 022 0100 70 022 0200 70 022 0200 19 End Pump Cover 70 020 0102 70 020 0102 70 020 0102 70 020 0102 70 020 0102 20 Filter Kit 70 054 010...

Page 14: ...eight pre paid If Pinnacle Climate Technologies Inc finds the item to be in normal operating condition or not defective the item will be returned freight collect This Limited Warranty is in lieu of al...

Page 15: ...ARA USO ESTERIOR Y USO INTERIOR PERO S LO EN REAS BIEN VENTILADAS EL USO EN INTERIORES S LO SE PERMITE PARA CALEFACCI N TEMPORAL DE EDIFICIOS ADECUADAMENTE VENTILADOS O ESTRUCTURAS EN CONSTRUCCI N MOD...

Page 16: ...P65Warnings ca gov ADVERTENCIA NO ENCIENDA EL CALENTADOR CUANDO LA C MARA EST CALIENTE ADVERTENCIA PELIGRO DE INCENDIO QUEMADURAS INHALACI N Y EXPLOSI N Mantenga los combustibles como materiales de c...

Page 17: ...seno Los calentadores de aire forzado de queroseno est n hechos expresamente para calefacci n temporal de edificios en construcci n modificaci n o reparaci n Fuego directo significa que todos los prod...

Page 18: ...de env o Nota Guarde la caja y los materiales de empaque para cuando guarde la unidad posteriormente Ilustrado con el cable opcional Enrolladores Enrolladores de cable Opcional Asa 1 Tornillos de 10 m...

Page 19: ...parador Llanta Soporte del eje ESPECIFICACIONES N de modelo 45 KFA 80T KFA 140T KFA 190T KFA 215T KFA Capacidad nominal BTU H kWh 45 000 13 2 80 000 23 4 140 000 41 190 000 55 7 215 000 63 Consumo de...

Page 20: ...una temporada a la siguiente El queroseno se deteriora con el tiempo EL QUEROSENO VIEJO NO SE QUEMAR ADECUADAMENTE EN ESTE CALENTADOR NOTA El queroseno debe almacenarse nicamente en un contenedor azu...

Page 21: ...ra es inferior a 0 F 18 C la pantalla mostrar LO Baja Cuando la temperatura es superior a 99 F 37 C la pantalla mostrar HI Alta Entre 0 F 18 C y 99 F 37 C la pantalla mostrar la temperatura real Apaga...

Page 22: ...RO DE COMBUSTIBLE El filtro de combustible debe limpiarse al menos dos veces por cada temporada de calefacci n Enjuague el filtro con queroseno K 1 limpio El combustible contaminado podr a hacer que s...

Page 23: ...alentador est funcionando gire la v lvula de seguridad hacia la derecha para aumentar la presi n o hacia la izquierda para disminuirla A continuaci n se muestra la presi n correcta de la bomba Modelo...

Page 24: ...ITOR 10UF 250 VCA CA 120 V 60 Hz INTERRUPTOR DE ENCENDIDO CONTROL DE L MITE AMARILLO FUSIBLE 8 A 125 VCA VERDE TIERRA BLANCO PCI DE CONTROL LUZ LED TERMOSTATO CONTROL DE TEMP FOTOC LULA SENSOR DE AMBI...

Page 25: ...resi n de la bomba 3 Limpie o reemplace la buj a 4 Limpie o reemplace el filtro de combustible 5 Limpie o reemplace la boquilla 6 Enjuague el interior del tanque con queroseno nuevo y limpio 7 Inspecc...

Page 26: ...NTE DE ALIMENTACI N 2020 Pinnacle Climate Technologies Inc Manual del usuario del calentador de aire forzado de queroseno VISTA DETALLADA S lo 45 KFA 80T KFA S lo 140T KFA 215T KFA 13 10 12 8 11 9 29...

Page 27: ...0 020 0101 70 020 0101 70 020 0401 70 020 0401 18 Juego de rotor 70 022 0100 70 022 0100 70 022 0100 70 022 0200 70 022 0200 19 Cubierta de la bomba 70 020 0102 70 020 0102 70 020 0102 70 020 0102 70...

Page 28: ...Pinnacle Climate Technologies Inc descubre que el art culo est en condiciones normales de funcionamiento o que no est defectuoso se devolver el art culo con el flete por cobrar Esta Garant a Limitada...

Reviews: