2018PC-P03/03
6
Fig. 7
SEE VENT
MANUFACTURER'S
INSTRUCTIONS
Check the load-bearing capacity of the floor, referring to the weight of the product given in the paragraph “
TECHNICAL DATA
”. If
the floor does not have a suitable load-bearing capacity, adequate countermeasures must be taken.
MINIMUM SAFETY DISTANCES
Install the product incompliance with the recommended safety distances
from heat sensitive or inflammable materials and not inflammable, from
load bearing and other walls and also from wooden elements, furniture,
etc.
The minimum distances are:
- 4”(10cm) fromthewallbehindthe stove;
- 6” (15 cm) from the side wall;
- 32”(80 cm) inthe heat radiationarea and from the the hot air fan
outlet.
In the case of flooring that is heat sensitive or inflammable the floor
must be protected with non-combustible insulating material, e.g. sheets
ofsteelplate,marble,tiles,etc.
The floor protection must extend:
- under the product;
- aminimumof6”(152mm)infrontofunitandbeyondeachsideof
the fuel loading and ash removal opening (4” / 10cm from the external
side of thecoating).
Connection to the flue must respect minimum safety distances from
heat-sensitive structural components or inflammable materials (wood
paneling, beams or ceilings, etc) shown in figures.
The stove will become hot while in operation. Keep children
away from all stovesurfaces.
Direct contact with stove while operating may cause skin
burns.
Keep any combustible product such as wooden furniture,
curtains, carpets, combustible liquids, etc. well away from the
stove when it is lit (minimum distance 32”/ 80 cm).
It is recommended that greater distances than those indicated
abovebeleftallroundthestovetomakeanynecessarywork
on the applianceeasier.
INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT
MANUFACTURER.
Certain local code restrictions may apply.
Check with Local Officials first before installing.
Fig.4
REAR WALL
SEEVENT
MANUFACTURER'S
INSTRUCTIONS
MIN4"
6"
4"
6"
FLOOR PROTECTION
32"
HEAT RADIATION AREA
Fig. 5
REAR WALL
6"
4"
6"
32"
6"
4"
Fig. 6
MIN 22"