background image

 

Programming the Hunter-Pro series with a LED keypad

 

15

   

 
 

Parameter Address 

Zone 5 Partition (1-8) 

308 

Zone 5 Partition (9-16) 

309 

Zone 6 Partition (1-8) 

310 

Zone 6 Partition (9-16) 

311 

Zone 7 Partition (1-8) 

312 

Zone 7 Partition (9-16) 

313 

Zone 8 Partition (1-8) 

314 

Zone 8 Partition (9-16) 

315 

Zone 9 Partition (1-8) 

316 

Zone 9 Partition (9-16) 

317 

Zone 10 Partition (1-8) 

318 

Zone 10 Partition (9-16) 

319 

Zone 11 Partition (1-8) 

320 

Zone 11 Partition (9-16) 

321 

Zone 12 Partition (1-8) 

322 

Zone 12 Partition (9-16) 

323 

Zone 13 Partition (1-8) 

324 

Zone 13 Partition (9-16) 

325 

Zone 14 Partition (1-8) 

326 

Zone 14 Partition (9-16) 

327 

Zone 15 Partition (1-8) 

328 

Zone 15 Partition (9-16) 

329 

Zone 16 Partition (1-8) 

330 

Zone 16 Partition (9-16) 

331 

Timers, Counters 

 

Entry Delay Time (1) 

332 

Entry Delay Time (2) 

333 

Exit Delay Time 

334 

Soak Days 

335 

Number of keystrokes for False 
Code 

336 

Pair Time 

337 

Double Knock time 

338 

Mains Fault Report Delay Time 

339 

User Bypass Limit Time 

340 

Phone Fault Report Delay Time 

341 

Number of System Inactivity days 
to Report  

342 

Wireless Zones Supervision Interval 
(Hrs) 

343 

Wireless Zones Supervision Interval 
(Mins) 

344 

Alarm Report Delay (Entry Rout) 

345 

Output Timers 

346 

External Siren Time 

346 

 

Parameter Address 

Internal Siren Time 

347 

Alarm  Output Time 

348 

Anti-Mask Output Time 

349 

Special Alarm 1 Output Time 

350 

Special Alarm 2 Output Time 

351 

Smoke Output Time 

352 

Fire Output Time 

353 

Special Fire Output Time 

354 

Panic Output Time 

355 

Silent Panic 

356 

Hold-Up 357 

Medical 358 

Tamper 359 

Mains Fault 

360 

Low Battery 

361 

Phone Fault 

362 

Zone Fault 

363 

Zone Bypass 

364 

GSM Transmitter Fault 

365 

Communication Fault 

366 

Ace Activating 

367 

Door Code 

368 

Wireless Remote 

369 

MS Test 

370 

Audio Control 

371 

PSTN/Cellular Remote 

372 

After Zone Closed Delay 

373 

General Parameters

 

General  Parameters Screen 1, 
Parameters 1-8 (1=2 Status Key 
2=DC Siren 3=Tamper 1 connected 
4=Tamper 1 EOL 5=Tamper 2 
connected 6=Tamper 2 EOL 
7=Key>Home 8=Auto Arm>Home) 

374 

General  Parameters Screen 1, 
Parameters 9-16 (9=Zone Bypass in 
Auto Arming 10=Two EOL 
Resistors 11=Siren Beep in Arming 
12=User Menu 13=Enhanced Menu 
14=N/A 15=Bypass Open Tamper 
in Arming 16=Bypass Fault in 
Arming) 

375 

General  Parameters Screen 2, 
Parameters 1-8 (1=Light Keypad 
Continuously 2=Light Keypad in 
Alarm 3=Light Keypad in Entry 
Delay 4=Buzzer in Alarm 5=Enable 
Fast Arming 6=Cancel Delay in 
Home1 7=Cancel Delay in Home 2 
8=Display Alarms in ARM) 

376 

 

Summary of Contents for Hunter-Pro RXN-416

Page 1: ...RXN 416 LED Keypad Installer Programming Guide For the Hunter Pro Series PIMA Electronic Systems Ltd www pima alarms com P N 4410289 A1 ZA en March 2009 ...

Page 2: ...id 57 Warning The user should follow the installation and operation instructions and among other things test the Product and the whole system at least once a week For various reasons including but not limited to changes in environment Warning The user should follow the installation and operation instructions and among other things test the Product and the whole system at least once a week For vari...

Page 3: ...e numbers 2 Discrete or toggle e g zone characteristics partitions etc these 2 state parameters represent or Both types are displayed by the keypad LEDs where an illuminating LED stands for 1 or enabled in discrete data and a turned off LED stands for 0 or disabled in discrete data In discrete programming mode the pound key is used for toggling the parameters value between and i e enabled and disa...

Page 4: ... LED keypad programming flow resembles the LCD keypad flow to some extent 2 1 The LEDs 1 When the system is in programming mode the Red Armed LED indicates by flashing fast The Green fault LED indicates whether the parameter s address is being set or its value Green LED Red LED Mode Flashes fast Off Programming inserting an address Flashes fast Flashes slowly Programming Inserting a value paramete...

Page 5: ...N HEX BIN HEX BIN 0 0000 4 0100 8 1000 C 1100 1 0001 5 0101 9 1001 D 1101 2 0010 6 0110 A 1010 E 1110 3 0011 7 0111 B 1011 F 1111 3 PROGRAMMING EXAMPLES 3 1 Displaying a number 1 Displaying a number that starts with 3 2 Displaying 6 as the 3rd digit of a number Account numbers are made of 4 digits therefor any account number that has less than 4 digits must be preceded with zeros For example accou...

Page 6: ...ation guide All the parameters with their addresses are listed in chapter 3 When programming discrete parameters reading the upper line is from left to right and so in the next screen the red illuminating LED i e the cursor is on the second parameter Advance the cursor with NEXT BACK buttons In the figure below the values demonstrated are where is enabled and is disabled 3 3 Example setting Mains ...

Page 7: ... displayed the hex digit of the upper line is 0001 which is decimal 1 therefor the cursor is on the first digit of the number value The bottom line displays 2 as the value digit 4 Press 3 the first digit of the new value 35 Just like in the LCD keypad when entering the first digit of a number value the stored number is erased and the cursor automatically advances to the second space which is now b...

Page 8: ... LED keypad are fully displayed even if only part of the field is in use In this example the requested value is a two digit number 35 but the Entry delay time field contains 3 digits and so the 3rd digit which is blank is displayed too 6 Press ENTR to save the new value and return to address programming mode 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 RXN 416 Armed Fault Programming mode Red Armed LED ...

Page 9: ...address table on chapter 4 Zone 3 characteristics menu byte 1 has the address of 252 Enter the installer code and press 252 The keypad will enter into programming mode and display the address 2 Press ENTR The keypad displays zone 3 current programmed characteristics If the menu contains more than 8 parameters see Figure 3 on page 4 ...

Page 10: ...ne 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 RXN 416 Armed Fault Cursor location third parameter left to right 4 Press the pound key to toggle the parameters value between and i e disabled and enabled As in the LCD keypad the value is changed and the cursor advances to the next parameter the 4th in this example 5 Press ENTR to save the data ...

Page 11: ... 33 PSTN Account ID10 34 Radio Account ID10 35 PSTN Account ID 11 36 Radio Account ID 11 37 Parameter Address PSTN Account ID 12 38 Radio Account ID 12 39 PSTN Account ID 13 40 Radio Account ID 13 41 PSTN Account ID 14 42 Radio Account ID 14 43 PSTN Account ID 15 44 Radio Account ID 15 45 PSTN Account ID 16 46 Radio Account ID 16 47 External Line access 48 Number of Rings 49 MS Dialing Number 50 C...

Page 12: ...2 Close 109 Power Fault 110 Power Restore 111 Phone Line Fault 112 Phone Line Restore 113 Open 114 Close 115 Parameter Address Test 116 Fuse Fail 117 Fuse Restore 118 Panic 119 False Code 120 Zone 1 Alarm Report 121 Zone 2 Alarm Report 122 Zone 3 Alarm Report 123 Zone 4 Alarm Report 124 Zone 5 Alarm Report 125 Zone 6 Alarm Report 126 Zone 7 Alarm Report 127 Zone 8 Alarm Report 128 Zone 9 Alarm Rep...

Page 13: ... Restore Report 195 Zone 6 Restore Report 196 Zone 7 Restore Report 197 Zone 8 Restore Report 198 Zone 9 Restore Report 199 Zone 10 Restore Report 200 Zone 11 Restore Report 201 Zone 12 Restore Report 202 Zone 13 Restore Report 203 Zone 14 Restore Report 204 Zone 15 Restore Report 205 Zone 16 Restore Report 206 Zone Fail Report 207 Zone Fail Restore Report 208 Zone Bypass 209 Installation Service ...

Page 14: ...aracteristics byte 1 266 Zone 10 Characteristics byte 2 267 Zone 11 Characteristics byte 1 268 Parameter Address Zone 11 Characteristics byte 2 269 Zone 12 Characteristics byte 1 270 Zone 12 Characteristics byte 2 271 Zone 13 Characteristics byte 1 272 Zone 13 Characteristics byte 2 273 Zone 14 Characteristics byte 1 274 Zone 14 Characteristics byte 2 275 Zone 15 Characteristics byte 1 276 Zone 15...

Page 15: ...ns 344 Alarm Report Delay Entry Rout 345 Output Timers 346 External Siren Time 346 Parameter Address Internal Siren Time 347 Alarm Output Time 348 Anti Mask Output Time 349 Special Alarm 1 Output Time 350 Special Alarm 2 Output Time 351 Smoke Output Time 352 Fire Output Time 353 Special Fire Output Time 354 Panic Output Time 355 Silent Panic 356 Hold Up 357 Medical 358 Tamper 359 Mains Fault 360 L...

Page 16: ...ren Type 384 Relay Type 385 Smoke Type 386 ON OFF Type 387 ALARM Type 388 Audio Control Type 389 OUT 1000 1 Type 390 OUT 1000 2 Type 391 OUT 1000 3 Type 392 OUT 1000 4 Type 393 OUT 1000 5 Type 394 OUT 1000 6 Type 395 OUT 1000 7 Type 396 OUT 1000 8 Type 397 IOR 1 Type 398 Parameter Address IOR 2 Type 399 IOR 3 Type 400 IOR 4 Type 401 IOR 5 Type 402 IOR 6 Type 403 IOR 7 Type 404 IOR 8 Type 405 IOR 9...

Page 17: ...isarm 479 Siren 2 Polarity Active 480 Relay Polarity Active 481 Smoke Polarity Active 482 Parameter Address ON OFF Polarity Active 483 Alarm Polarity Active 484 Audio Control Polarity Active 485 OUT 1000 1 Polarity Active 486 OUT 1000 2 Polarity Active 487 OUT 1000 3 Polarity Active 488 OUT 1000 4 Polarity Active 489 OUT 1000 5 Polarity Active 490 OUT 1000 6 Polarity Active 491 OUT 1000 7 Polarity...

Page 18: ...Start Mins 550 User 2 Stop Hrs 551 User 2 Stop Mins 552 User 3 Start Hrs 553 User 3 Start Mins 554 User 3 Stop Hrs 555 User 3 Stop Mins 556 User 4 Start Hrs 557 User 4 Start Mins 558 User 4 Stop Hrs 559 Parameter Address User 4 Stop Mins 560 User 5 Start Hrs 561 User 5 Start Mins 562 User 5 Stop Hrs 563 User 5 Stop Mins 564 User 6 Start Hrs 565 User 6 Start Mins 566 User 6 Stop Hrs 567 User 6 Stop...

Page 19: ...616 User 5 Partition 1 8 617 User 5 Partition 9 16 618 User 6 Partition 1 8 619 User 6 Partition 9 16 620 User 7 Partition 1 8 621 User 7 Partition 9 16 622 User 8 Partition 1 8 623 User 8 Partition 9 16 624 User 9 Partition 1 8 625 User 9 Partition 9 16 626 User 10 Partition 1 8 627 User 10 Partition 9 16 628 User 11 Partition 1 8 629 User 11 Partition 9 16 630 User 12 Partition 1 8 631 User 12 P...

Reviews: