Safety
Operating Manual PSSu K S 16DO 0.5
22059-EN-08
9
3
Safety
3.1
Intended use
The module provides type 1 outputs in accordance with IEC 61131-2. It may be used to
switch:
}
Resistive loads
}
Inductive loads
}
Capacitive loads
The module PSSu K S 16DO 0.5 may be used as a safety component in accordance with
the Lifts Directive 95/16/EC, EN 81-1, EN 81-2 and EN 115-1.
The programmable safety system should be installed in a protected environment that meets
at least the requirements of pollution degree 2. Example: Protected inside space or control
cabinet with protection class IP54 and corresponding air conditioning.
Intended use includes making the electrical installation EMC-compliant. Please refer to the
guidelines stated in the "PSSuniversal Installation Manual". The module is designed for use
in an industrial environment. It is not suitable for use in a domestic environment, as this can
lead to interference.
The following is deemed improper use in particular:
}
Any component, technical or electrical modification to the module
}
Use of the module outside the areas described in this manual
}
Any use of the module that is not in accordance with the technical details.
INFORMATION
The module is supported by:
}
PSSuniversal Configurator and PSSuniversal Assistant from Version
1.8.1.
}
PAS4000 from version 1.7.0
– We recommend that you always use the latest version (download
from www.pilz.de).
The PSSu K S 16DO 0.5 module may be used with the following connectors with spring-
loaded terminals:
}
PSSu A Con 1/10 C
}
PSSu A Con 3/30 C
WARNING!
The module may
not
be used in combination with PSSu E F BSW(-T) mod-
ules in safety-related applications.