Installation
Operating Manual PSSu K S 16DO 0.5
22059-EN-08
17
5.3
Install/uninstall connector
We recommend that the connectors with spring-loaded terminals are wired before they are
plugged in.
Please note:
}
All contacts should be protected from contamination.
}
The mechanics of the connector are designed for 25 plug in/out cycles.
Installation procedure:
}
Plug the connector into the required connector strip until you hear it lock into position
[1].
INFORMATION
The two locking levers automatically hook into place when plugged in. As a
result the connector is firmly connected to the module.
Schematic representation:
[1]
Uninstallation procedure:
}
Push both locking levers to the left, as far as they will go [1].
INFORMATION
This will automatically lift the connector, which can then be removed from
the module.