Fig.: Example for using deviating mirrors
Legende
[1] Transmitter
[2] Receiver
[3] Hazardous area
[4] Deviating mirrors
[5] Minimum safety distance
[6] Distance between the deviating mirrors (see the following table)
[7] Distance from transmitter to deviating mirror
[8] Distance from deviating mirror to receiver
Number of mirrors per device
in
m
1
6.4 m (8 m – 20 %)
2
5.12 m (8 m – 2 x 20 %)
Dead zones
Use of the standard installation kit results in a dead zone of 15.4 mm on both sides of the
safety light grid.
If you want to use the safety light grid without dead zones, use the
PSEN opII Adv Bracket Kit for safety light grid installation (see
Use the installation information provided in the PSEN opII Adv Bracket Kit operating
manual.