PSEN opII4H Series
Operating Manual PSEN opII4H Series
1003501-EN-02
28
Orientation
General guidelines
For the safety light grid to function properly, the transmitter and receiver must be correctly
aligned.
The transmitter and receiver on the safety light grid can be aligned with our without the help
of a laser alignment aid.
}
Alignment with laser alignment aid: the safety light grid does not need to be switched on
}
Alignment without laser alignment aid: the safety light grid must already be wired (see
chapter entitled "Wiring" in the safety grid's operating manual) and must be switched on
For alignment Pilz recommends the PSEN opII Laserpointer (see
) or another laser alignment aid.
[3]
[1]
[2]
Fig.: Transmitter/receiver modification directions during orientation
Legende
[1] Vertical: by vertical shifting of position in the elongated holes in the top and bottom
flexible brackets
[2] Horizontal: by horizontal shifting of position in the elongated holes in the top and bot-
tom flexible brackets
[3] The axis orientation can be changed by rotating the flexible bracket right or left
Pilz recommends that modifications to the orientation of the transmitter/receiver be made in
the following sequence:
1. Vertical modification
2. Horizontal modification
3. Axis orientation modification