PSEN ma1.3b-24 VA
Operating Manual PSEN ma1.3b-24 VA
22227-EN-03
| 17
Technical details
General
Certifications
ATEX, CE, EAC (Eurasian), ECOLAB, TÜV, UL/
cUL
Sensor's mode of operation
Magnetic
Coding level in accordance with EN ISO 14119
Low
Design in accordance with EN ISO 14119
4
Classification in accordance with EN 60947-5-3
PDDB
Electrical data
Supply voltage
Voltage
24 V
Kind
DC
Voltage tolerance
-20 %/+10 %
Max. switching frequency
1 Hz
Lowest operating current (Im)
1 mA
Max. voltage drop (Ud)
3,5 V
Switching voltage
24 V
Internal resistance safety contacts
10 Ohm
Max. switching current, safety contacts
0,14 A
Max. breaking capacity, safety contacts
2,6 W
Max. switching current, auxiliary contacts
7 mA
Utilisation category in accordance with EN 60947-1
DC-12
Max. continuous current safety contacts
0,1 A
Times
Reaction time (actuator removed)
2 ms
Environmental data
ATEX certification
SEV 17 ATEX 0155 X
ATEX category, gas
II 3G Ex mc IIC T6 Gc
ATEX category, dust
II 3D Ex mc IIIC T80°C Dc
Application area
X: -25°C ≤ ta ≤ +55°C
Ambient temperature
Temperature range
-25 - 55 °C
Climatic suitability
In accordance with the standard
IEC 60068-2-30
Humidity
90 % r. h. at 40 °C
Max. operating height above sea level
4000 m
EMC
EN 60947-5-3
Vibration
In accordance with the standard
EN 60947-5-2
Frequency
10 - 55 Hz
Amplitude
1 mm
Shock stress
Acceleration
30g
Duration
11 ms