Technical details actuator

General

540180

541180

Certifications

CE, TÜV, cULus Listed

CE, EAC (Eurasian), TÜV, cULus
Listed

Sensor's mode of operation

Transponder

Transponder

Coding level in accordance with EN
ISO 14119

High

High

Pilz coding type

fully coded

fully coded

Transponder

540180

541180

Frequency band

122 kHz - 128 kHz

122 kHz - 128 kHz

Max. transmitter output

7 dBm

7 dBm

Environmental data

540180

541180

Ambient temperature

In accordance with the standard

EN 60068-2-14

EN 60068-2-14

Temperature range

-25 - 70 °C

-25 - 70 °C

Storage temperature

In accordance with the standard

EN 60068-2-1/-2

EN 60068-2-1/-2

Climatic suitability

In accordance with the standard

EN 60068-2-78

EN 60068-2-78

Humidity

93 % r. h. at 40 °C

93 % r. h. at 40 °C

EMC

EN 60947-5-3

EN 60947-5-3

Vibration

In accordance with the standard

EN 60947-5-2

EN 60947-5-2

Frequency

10 - 55 Hz

10 - 55 Hz

Amplitude

1 mm

0,35 mm

Shock stress

In accordance with the standard

EN 60947-5-2

EN 60947-5-2

Acceleration

30g

30g

Duration

11 ms

18 ms

Protection type

Housing

IP6K9K

IP6K9K

Mechanical data

540180

541180

Material

Top

PBT

PBT

Max. torque setting for fixing
screws

1 Nm

0,8 Nm

Dimensions

Height

11 mm

37 mm

Width

40 mm

18 mm

Depth

40 mm

18 mm

Weight

20 g

11 g

Where standards are undated, the 2016-10 latest editions shall apply.

Summary of Contents for PSEN cs4.1p/M12

Page 1: ...PSEN cs4 1p M12 Operating Manual 1003293 EN 08 PSEN sensor technology...

Page 2: ...nta tion will be gratefully received Source code from third party manufacturers or open source software has been used for some components The relevant licence information is available on the Internet...

Page 3: ...bility 8 Disposal 8 For your safety 8 Unit features 9 Function description 10 Safety Device Diagnostics 11 Operating distances 12 Lateral and vertical offset 12 Wiring 13 Terminal assignment connector...

Page 4: ...8 4 Technical details safety switch 28 Technical details actuator 32 Safety characteristic data 33 Supplementary data 34 Radio approval 34 Order reference 34 Safety switch 34 Actuator 34 Complete syst...

Page 5: ...mportant is identified as follows DANGER This warning must be heeded It warns of a hazardous situation that poses an immediate threat of serious injury and death and indicates preventive measures that...

Page 6: ...ollowing combinations from safety switch and actuators are permitted Safety switch Approved actuators PSEN cs4 1 M12 8 0 15m PSEN cs4 1 PSEN cs2 1 PSEN cs4 1p PSEN cs4 1 PSEN cs2 1 The safety level PL...

Page 7: ...unction for example PSEN ix2 F4 code PSEN ix2 F8 code PDP67 F 4 code PSEN Y junction M12 sensor PSEN Y junction M12 cable You will need to be conversant with the information in these documents in orde...

Page 8: ...ss of safety function due to manipulation of the interlocking device Manipulation of the interlocking device may lead to serious injury and death You should prevent any possibility of the interlocking...

Page 9: ...n to perform actions and to read configuration parameters Manipulation protection in accordance with ISO 14119 chap 7 2 d is possible by verifying the short name of the actuator through the controller...

Page 10: ...If one safety input switches from high to low while the other safety input remains high an unequal status is displayed Input LED flashes yellow If this safety input switches back from low to high whi...

Page 11: ...the fieldbus module Poll information of the sensors examples what sensor in the series has switched at what point could there be an open circuit in the series connection Read configuration parameters...

Page 12: ...inet Further information on Safety Device Diagnostics can be found in Additional documents that apply 7 Operating distances Sao So Sr Sar mm Somin On Off Legend Sao Assured operating distance Somin Mi...

Page 13: ...lmax in the input circuit is calculated from the max cable capacitance at the safety outputs see Technical data 28 the minimum permitted supply voltage at the sensor 19 2 V The power supply must meet...

Page 14: ...t channel 2 white 2 A1 24 VUB brown 3 12 Output channel1 green 4 22 Output channel2 yellow 5 Y32 Signal output diagnostic output grey 6 S11 Input channel 1 pink 7 A2 0 V UB blue 8 Y1 Diagnostics input...

Page 15: ...PSEN cs4 1p M12 Operating Manual PSEN cs4 1p M12 1003293 EN 08 15 Single connection Connection diagram single connection without SDD Actuator Safety switch Evaluation device...

Page 16: ...ating Manual PSEN cs4 1p M12 1003293 EN 08 16 Connection diagram single connection with SDD S21 S11 24 V 0 V A1 A2 12 22 I2 FS I1 FS FS Failsafe A1 A2 Y1 Y32 Rx Tx Actuator Safety switch Evaluation de...

Page 17: ...d by the application Ensure there is sufficient supply voltage taking inrush currents and fusing into considera tion CAUTION Extension of delay on de energisation When several n devices are connected...

Page 18: ...M12 Operating Manual PSEN cs4 1p M12 1003293 EN 08 18 Connection diagram series connection without SDD Actuator Actuator Control system Evaluation device Safety switch 1 Safety switch 2 Safety switch...

Page 19: ...ion diagram series connection with SDD S11 S21 24 V 0 V A1 A2 12 22 I1 FS I2 FS FS Failsafe ST Standard S11 S21 S11 S21 12 22 12 22 A1 A2 A1 A2 Y1 Y1 Y1 Y32 Y32 Y32 Tx Rx Actuator Safety switch Evalua...

Page 20: ...itch type 3 PSS for safety gate monitoring with standard function block SB064 SB066 or FS_Safety Gate The correct connection to the respective evaluation device is described in the operating manual fo...

Page 21: ...se range To teach in a new actuator A maximum of 8 learning procedures are possible 1 The actuator that is to be taught in must be brought into the safety switch s response range as the only transpond...

Page 22: ...tuators should be permanently secured us ing M5 safety screws with a flat head e g M5 cheese head or pan head screws Torque setting Please note the information provided under Technical details 28 The...

Page 23: ...crew on the safety switch 3 Attach the screws for the actuator leaving a distance of 3 6 mm between the screw head and plate 4 Slide the actuator on to the screws The arrows on the labelled surfaces o...

Page 24: ...ch see diagram 3 8 Use the seals 2 to close the unused mounting holes on the actuator see diagram 2 Safety switches PSEN cs4 1 with actuator PSEN cs2 1 1 Drill holes in the mounting surface to secure...

Page 25: ...E The safety function should be checked after initial commissioning and each time the plant machine is changed The safety functions may only be checked by qualified personnel Status indicators Power F...

Page 26: ...PSEN cs4 1p M12 Operating Manual PSEN cs4 1p M12 1003293 EN 08 26 Dimensions in mm Safety switch PSEN cs4 1p 19 8 18 26 4 R 8 4 5 22 37 M8 33 26 140 10...

Page 27: ...cs4 1p M12 Operating Manual PSEN cs4 1p M12 1003293 EN 08 27 Safety switch PSEN cs4 1 M12 8 0 15m 19 8 18 26 4 R 8 4 5 22 37 M12 48 5 31 160 10 Actuator 40 11 16 2 x 5 3 5 30 30 5 4 Fig Actuator PSEN...

Page 28: ...9 4 4 Classification in accordance with EN 60947 5 3 PDDB PDDB Pilz coding type fully coded fully coded Transponder 541159 541160 Frequency band 122 kHz 128 kHz 122 kHz 128 kHz Max transmitter output...

Page 29: ...0 A 20 A Voltage drop at OSSDs 3 5 V 3 5 V Lowest operating current 0 mA 0 mA Utilisation category in accordance with EN 60947 1 DC 12 DC 12 Times 541159 541160 Test pulse duration safety outputs 450...

Page 30: ...h the standard EN 60947 5 2 EN 60947 5 2 Frequency 10 55 Hz 10 55 Hz Amplitude 1 mm 1 mm Shock stress In accordance with the standard EN 60947 5 2 EN 60947 5 2 Acceleration 30g 30g Duration 18 ms 18 m...

Page 31: ...25 mm 25 mm Assured release distance Sar 33 mm 33 mm Typical release distance Sr 29 mm 29 mm Repetition accuracy switching distances 10 10 Change of operating distance with temperature changes 0 1mm...

Page 32: ...25 70 C 25 70 C Storage temperature In accordance with the standard EN 60068 2 1 2 EN 60068 2 1 2 Climatic suitability In accordance with the standard EN 60068 2 78 EN 60068 2 78 Humidity 93 r h at 40...

Page 33: ...data The SIL CL value in accordance with EN 62061 corresponds to the SIL value in accord ance with EN 61508 TM is the maximum mission time in accordance with EN ISO 13849 1 The value also ap plies as...

Page 34: ...ay cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the i...

Page 35: ...ocket Open cable 3 m 540 319 5 m 540 320 10 m 540 321 20 m 540 333 30 m 540 326 PSEN cable M12 8af Angled M12 8 pin socket Open cable 3 m 540 322 5 m 540 323 10 m 540 324 30 m 540 325 PSEN cable M12 8...

Page 36: ...pin socket M12 8 pin pin M8 8 pin socket 540 337 PSEN Y junction M12 M12 M12 PIGTAIL M12 8 pin socket M12 8 pin pin M12 8 pin socket 540 338 PDP67 F 4 code Decentralised passive junction 773 603 PDP67...

Page 37: ...requirements of the following directives of the European Parliament and of the Council 2006 42 EC on machines 2014 53 EC on radio equipment The complete EC Declaration of Conformity is available on t...

Page 38: ...NET p THE SPIRIT OF SAFETY are registered and protected trademarks of Pilz GmbH Co KG in some countries We would point out that product features may vary from the details stated in this document depen...

Reviews: