PSEN cs4.1p/M12
Operating Manual PSEN cs4.1p/M12
1003293-EN-08
| 25
4. Fix the actuator.
The arrows on the labelled surfaces of the safety switch and actuator must face each
other. Align the actuator and tighten the screws.
5. Align the safety switch and tighten the screws.
Adjustment
}
The stated operating distances (see
) only apply when the
safety switch and actuator are installed facing each other in parallel. Operating distances
may deviate if other arrangements are used.
}
Note the maximum permitted lateral and vertical offset (see
and
Operation
NOTICE
The safety function should be checked after initial commissioning and each
time the plant/machine is changed. The safety functions may only be
checked by qualified personnel.
Status indicators
:
}
"Power/Fault" LED lights up green: The unit is ready for operation
}
"Safety Gate" LED lights up yellow: Actuator is within the response range
}
"Input" LED lights up yellow: There is a high signal at both inputs
Fault indicator
:
}
"Input" LED lights up yellow: the signal switches from high to low at one input, while a
high signal remains on the other input (partial operation).
Remedy: Open both channels of the input circuit.
}
"Power/Fault" LED lights up red: Error message
Remedy: Rectify fault and interrupt power supply.
Please note the different times for
}
The switch-on delay after UB is applied
}
The recovery time of the sensor and evaluation device.