background image

 

The Best of 

German 

Engineering

Partner of:

Support

Technical support is available from Pilz round the clock. 

Americas

Brazil

+55 11 97569-2804

Canada

+1 888-315-PILZ (315-7459)

Mexico

+52 55 5572 1300

USA (toll-free)

+1 877-PILZUSA (745-9872)

Asia

China

+86 21 60880878-216 

Japan

+81 45 471-2281

South Korea

+82 31 450 0680

Australia

+61 3 95600621

Europe

Austria

+43 1 7986263-0

Belgium, Luxembourg

+32 9 3217575

France

+33 3 88104000

Germany

+49 711 3409-444

Ireland

+353 21 4804983

Italy, Malta

+39 0362 1826711

Scandinavia

+45 74436332

Spain

+34 938497433

Switzerland

+41 62 88979-30

The Netherlands

+31 347 320477

Turkey

+90 216 5775552

United Kingdom

+44 1536 462203

You can reach our  
international hotline on:  

+49 711 3409-444  
[email protected]

CMSE

®

, Indur

aNET p

®

, P

AS4000

®

, P

AScal

®

, P

ASconfig

®

, P

ilz

®

, PIT

®

, PLID

®

, PMCprimo

®

, PMCpr

ot

ego

®

, PMCt

endo

®

, PMD

®

, PMI

®

, PNO

Z

®

, P

rimo

®

, PSEN

®

, PSS

®

, PVIS

®

, SafetyBUS p

®

,  

SafetyEYE

®

, SafetyNET p

®

, THE SPIRIT OF SAFET

Y

®

 ar

e r

egist

er

ed and pr

ot

ect

ed tr

ademarks of P

ilz GmbH & Co. K

G in some countries. W

e would point out that pr

oduct featur

es may var

 

from the details stat

ed in this document, depending on the status at the time of publication and the scope of the equipment. W

e accept no r

esponsibility for the validity, accur

acy

  

and entir

ety of the t

ext and gr

aphics pr

esent

ed in this information. Please contact our T

echnical Suppor

t if you have any questions.

Pilz develops environmentally-friendly products using  
ecological materials and energy-saving technologies.  
Offices and production facilities are ecologically designed, 
environmentally-aware and energy-saving. So Pilz offers 
sustainability, plus the security of using energy-efficient  
products and environmentally-friendly solutions.

Pilz GmbH & Co. KG 
Felix-Wankel-Straße 2 
73760 Ostfildern, Germany
Tel.: +49 711 3409-0 
Fax: +49 711 3409-133 
[email protected]
www.pilz.com

200XXXX-EN-0X

0-0-2-3-000, 2017-00 P

rint

ed in Germany

© P

ilz GmbH & Co. K

G, 2017

Back cover

21400-EN-10, 2017-06 Printed in Germany

© Pilz GmbH & Co. KG, 2015

Summary of Contents for PNOZ s8

Page 1: ...PNOZ s8 Operating Manual 21400 EN 10 Safety relays...

Page 2: ...nta tion will be gratefully received Source code from third party manufacturers or open source software has been used for some components The relevant licence information is available on the Internet...

Page 3: ...ranty and liability 7 Disposal 7 For your safety 7 Unit features 8 Safety features 8 Block diagram terminal configuration 8 Function description 9 Timing diagram 9 Installation 9 Wiring 10 Preparing f...

Page 4: ...Contents Operating Manual PNOZ s8 21400 EN 10 4 Remove plug in terminals 19 Order reference 19 EC declaration of conformity 19...

Page 5: ...y important is identified as follows DANGER This warning must be heeded It warns of a hazardous situation that poses an immediate threat of serious injury and death and indicates preventive measures t...

Page 6: ...the areas described in this manual Use of the product outside the technical details see Technical details 13 NOTICE EMC compliant electrical installation The product is designed for use in an industri...

Page 7: ...e generic and specialist standards applicable to the spe cific application Warranty and liability All claims to warranty and liability will be rendered invalid if The product was used contrary to the...

Page 8: ...ts the following safety requirements The unit monitors its own output contacts The safety function remains effective in the case of a component failure Earth fault in the feedback loop Detected depend...

Page 9: ...terminator is inserted at the side of the unit Connect base unit and PNOZsigma contact expansion module Remove the plug terminator at the side of the base unit and at the contact expander module Conn...

Page 10: ...chnical details 13 Rl km cable resistance km Use copper wire that can withstand 60 75 C Sufficient fuse protection must be provided on all output contacts with capacitive and in ductive loads Ensure t...

Page 11: ...the mechanical contact on the relay cannot be tested automatically Depending on the operational environment measures to detect the non opening of switching elements may be required under some circums...

Page 12: ...indicators FAULT Diagnostics Internal error unit defective Remedy Switch supply voltage off and then on again change unit if neces sary Faults malfunctions Contact malfunctions If the contacts have w...

Page 13: ...750108 751108 Number 1 1 Voltage at Input circuit DC 24 V 24 V Current at Input circuit DC 65 mA 65 mA Max inrush current impulse Current pulse input circuit 0 6 A 0 6 A Pulse duration input circuit...

Page 14: ...h UL Voltage 240 V AC G P 240 V AC G P With current 3 A 3 A Voltage 24 V DC G P 24 V DC G P With current 3 A 3 A Pilot Duty B300 R300 B300 R300 External contact fuse protection safety contacts In acco...

Page 15: ...947 1 EN 60947 1 Overvoltage category III II III II Pollution degree 2 2 Rated insulation voltage 250 V 250 V Rated impulse withstand voltage 4 kV 4 kV Protection type Housing IP40 IP40 Terminals IP20...

Page 16: ...comply with the safety related characteristic data in order to achieve the required safety level for your plant machine Operating Mode EN ISO 13849 1 2015 PL EN ISO 13849 1 2015 Category EN 62061 SIL...

Page 17: ...in the service life table are not accessible the stated PFH value can be used irrespective of the switching frequency and the load as the PFH value already considers the relay s B10d value as well as...

Page 18: ...e category Max rated impulse withstand voltage 3000 m 150 V II 2 5 kV 100 V III 2 5 kV 4000 m 150 V II 2 5 kV 100 V III 2 5 kV 5000 m 100 V II 1 5 kV 24 V III 0 8 kV Reduction of rated insulation volt...

Page 19: ...nection type Order No PNOZ s8 24 VDC Screw terminals 750 108 PNOZ s8 C 24 VDC Spring loaded terminals 751 108 EC declaration of conformity This product these products meet the requirements of the dire...

Page 20: ...yNET p THE SPIRIT OF SAFETY are registered and protected trademarks of Pilz GmbH Co KG in some countries We would point out that product features may vary from the details stated in this document depe...