Transport and storage
Operating Manual PMCtendo SZ
1002405-EN-04
16
4
Transport and storage
4.1
Transport
Secure the shafts and bearings of a synchronous servo motor against impacts during trans-
port. During transport, use the corresponding eyebolts (if present) and a suitable fastening
element.
Lift the synchronous servo motor by the eyebolts exclusively without additional attach-
ments. Never transport the motor by the fan hoods or the angle flange socket of the con-
nectors.
4.2
Storage
Store synchronous servo motors in enclosed, dry spaces. Storage on the fan hoods is not
permitted. If the motors are protected against all damaging environmental influences and
mechanical damage, short-term storage in outdoor areas with roofing is permitted.
Make sure that no condensate forms during storage, such as due to extreme temperature
fluctuations with high humidity.
Be sure to protect the motor shaft against corrosion in the case of long-term storage. Be
aware that the insulation resistance of the winding must be tested after long-term storage.