Commissioning
Operating Manual PMCtendo SZ
1002405-EN-04
39
7.2
Checking the motor connection
WARNING!
Risk of injury due to moving parts!
Make sure that:
– No one is put at risk by starting up the motor.
– All protective and safety devices are properly installed, even in test
operation.
– Components attached to the drive are sufficiently secured against
centrifugal forces (feather keys, coupling elements, etc.).
ü
You have connected a synchronous servo motor as described in the chapter
Connec-
tion method [
25]
.
a
Check whether the grounding was established properly.
a
Check whether all live parts are protected against unintentional or intentional contact.
a
Check whether the rotor of the synchronous servo motor can turn freely.
a
Check the direction of rotation of the synchronous servo motor by actuating it using the
corresponding servo amplifier (also observe the documentation of the servo amplifier).
a
Check the function of the motor brake by applying control voltage to it (note the polar-
ity). The motor brake must be released.