PNOZ s9
Operating Manual PNOZ s9
21401-EN-10
19
POWER
Diagnostics: Supply voltage too low
}
Remedy: Check supply voltage and increase if necessary.
RESET
FAULT
Diagnostics: Position of rotary switch is not permitted or rotary switch was ad-
justed during operation.
}
Remedy: Switch supply voltage off and then on again.
POWER, IN1, IN2, OUT, RESET, FAULT
Diagnostics: The operating mode selector switch "mode" is in its start position
(vertical position)
}
Remedy: Switch off the supply voltage and set the required operating mode
on operating mode selector switch "mode".
Faults - malfunctions
}
Contact malfunctions: If the contacts have welded, reactivation will not be possible after
the input circuit has opened.
}
In the case of an error, the delay-on de-energisation contacts may open before the
delay time has elapsed.
Dimensions in mm
*with spring-loaded terminals
120 (4.72")
* 100 (3,94")
98 (3.86")
17,5
(0.69")