Device features
}
Safe guard locking for swing gates and sliding gates
}
Safe interlocking (position monitoring)
}
Transponder technology
}
2 safety inputs for series connection of multiple safety switches
}
2 safety outputs
}
Safety Device Diagnostics (SDD)
– Safety Device Diagnostics can be used to poll sensor information, to perform actions
and to read configuration parameters
– Manipulation protection in accordance with ISO 14119 is possible by verifying the
short name of the actuator through the controller via SDD communication
}
Diagnostic input for Y1 for Safety Device Diagnostics (SDD)
}
Signal output/diagnostic output Y32 for Safety Device Diagnostics
}
Monitoring of shorts between the safety outputs
}
Guard locking element keeps the safety gate from being opened unintentionally
}
Auxiliary release for opening the safety gate
}
1 signal output
}
Suitable for left and right hinged safety gates
}
Pilz coding type
– PSEN ml sa 1.1: coded
– PSEN ml sa 2.1: fully coded
– PSEN ml sa 2.2: uniquely coded
}
M12, 12-pin male connector
}
LEDs:
– Supply voltage/fault
– Status of actuator
– Status of guard locking
– Input lights up yellow (without function)
}
Escape release in accordance with EN ISO 14119
The escape release enables manual release of guard locking from
inside
the danger
zone without aids and corresponds to escape unlocking.
}
Actuator with door handles and integrated escape release