Technical details
Operating Manual PSEN ml s 1.1/2.1/2.2
1004710-EN-05
| 74
Semiconductor outputs 570406
570408
570410
Number of OSSD safety
outputs
2
2
2
Signal outputs
1
1
1
Switching current per out-
put
100 mA
100 mA
100 mA
Breaking capacity per out-
put
2,4 W
2,4 W
2,4 W
Potential isolation from
system voltage
No
No
No
Short circuit-proof
yes
yes
yes
Residual current at out-
puts
100 µA
100 µA
100 µA
Voltage drop at OSSDs
1 V
1 V
1 V
Conditional rated short cir-
cuit current
100 A
100 A
100 A
Lowest operating current
1 mA
1 mA
1 mA
Utilisation category in ac-
cordance with EN
60947-1
DC-13
DC-13
DC-13
Times
570406
570408
570410
Test pulse duration, safety
outputs
450 µs
450 µs
450 µs
Switch-on delay
after UB is applied
1,1 s
1,1 s
1,1 s
Inputs typ.
1 ms
1 ms
1 ms
Inputs max.
3 ms
3 ms
3 ms
Actuator typ.
30 ms
30 ms
30 ms
Actuator max.
50 ms
50 ms
50 ms
Delay-on de-energisation
Inputs typ.
3 ms
3 ms
3 ms
Inputs max.
5 ms
5 ms
5 ms
Actuator typ.
30 ms
30 ms
30 ms
Actuator max.
40 ms
40 ms
40 ms
Risk time in accordance
with EN 60947-5-3
260 ms
260 ms
260 ms
Supply interruption before
de-energisation
20 ms
20 ms
20 ms
Simultaneity, channel 1
and 2 max.
20 ms
20 ms
20 ms
Pulse duration Lock/Un-
lock Request
350 - 400 ms
350 - 400 ms
350 - 400 ms
Processing time activate/
deactivate guard locking
100 ms
100 ms
100 ms
Environmental data
570406
570408
570410
Temperature of metal sur-
face at ambient temperat-
ure: 25 °C
40 °C
40 °C
40 °C