Installation
Operating Manual PSEN ml s 1.1/2.1/2.2
1004710-EN-05
| 45
8.4
Actuator installation
8.4.1
Installation without mounting bracket
ø
5
,3
5
ø 10
4
8
Actuator, no mounting bracket
Provide the mounting surface with tapped
holes for two M5 screws (see diagram).
1. Attach the actuator to the gate.
2. Use two M5 screws to fix the actuator to the mounting surface.
8.4.2
Installation with mounting bracket
ø 6,5
Actuator, with mounting bracket
Provide the mounting surface with tapped
holes for two M6 screws (see Dimensions).
(Diagram: order no. 570 492 as example)
1. Use two M6 screws to fix the mounting bracket to the gate. The position of the drill
holes can be taken from the section entitled Dimensions.
2. Use two M5 screws to fix the actuator to the mounting bracket.
Fig.: Actuator, installed on mounting bracket