Connection to control systems and evaluation devices
Operating Manual PSEN ml s 1.1/2.1/2.2
1004710-EN-05
| 35
The following options are available for connecting the safety switch in a series connection:
}
Wiring with the safety control system via PSEN ml Y junction
3 x PSEN ml s
X1
X2
X3
X1
X2
X3
X1
X2
Safety control system
8-core
12-core
[1]
[2]
Legend
[1] PSEN ml Y junction M12
[2] PSEN ml end adapter
}
When establishing the series connections with connection to the safety control system,
use the following adapters:
– PSEN ml Y junction M12
– PSEN ml end adapter
}
Connection in the control cabinet at the terminal block
– Connect the 12-core cables of the safety switch to the terminal block of the control
cabinet.
6.5
Connection to Pilz evaluation devices
The safety switch can be connected to Pilz evaluation devices.
Suitable Pilz evaluation devices are, for example:
}
PNOZmulti for safety gate monitoring
Configure the switch in the PNOZmulti Configurator with switch type 3.
}
PSSuniversal PLC for safety gate monitoring with function block FS_SafetyGate
The correct connection to the respective evaluation device is described in the operating
manual for the evaluation device. Make sure that the connection is made in accordance
with the specifications in the operating manual for the selected evaluation device.