Accessories

Cable

Product type

Connection 1

Connection 2

Length

Order no.

PSEN Kabel Winkel/cable
angleplug 2m

Female connector, M8
angled, 4-pin

Open cable end

2 m

533 110

PSEN Kabel Winkel/cable
straightplug2m

Female connector, M8
straight, 4-pin

2 m

533 111

PSEN Kabel Winkel/cable
angleplug 5m

Female connector, M8
angled, 4-pin

5 m

533 120

PSEN Kabel Gerade/cable
straightplug 5m

Female connector, M8
straight, 4-pin

5 m

533 121

PSEN Kabel Winkel/cable
angleplug 10m

Female connector, M8
angled, 4-pin

10 m

533 130

PSEN Kabel Winkel/cable
straightplug10m

Female connector, M8
straight, 4-pin

10 m

533 131

PSEN Kabel Winkel/cable
angleplug 3m

Female connector, M8
angled, 4-pin

30 m

533 140

PSEN Kabel Winkel/cable
straightplug30m

Female connector, M8
straight, 4-pin

30 m

533 141

PSS67 Cable M8sf M12sm Female connector, M8

straight, 4-pin

Male connector M12
straight

3 m

380 200

5 m

380 201

10 m

380 202

30 m

380 203

PSS67 Cable M8af M12sm Female connector M8

angled, 4-pin

3 m

380 204

5 m

380 205

10 m

380 206

30 m

380 207

Installation materials

Product type

Features

Order no.

PSEN Winkel / bracket

Mounting bracket

532 110

Connector

Product type

Features

Order no.

PSEN ma adapter

Adapter for connecting the safety switch to PSS67 and PDP67

380 300

Summary of Contents for 503220

Page 1: ...PSEN 2 2p 20 Operating Manual 20915 EN 08 PSEN sensor technology...

Page 2: ...umentation will be gratefully received Source code from third party manufacturers or open source software has been used for some components The relevant licence information is available on the Interne...

Page 3: ...6 Warranty and liability 6 Disposal 6 For your safety 7 Unit features 7 Function description 7 Block diagram 8 Operating distances 8 Lateral and vertical offset 9 Wiring 9 Pin assignment 10 Requireme...

Page 4: ...ticularly important is identified as follows DANGER This warning must be heeded It warns of a hazardous situation that poses an immediate threat of serious injury and death and indicates preventive me...

Page 5: ...wing components Actuator PSEN 2 2 20 Interface PSEN i1 see Order reference 19 and a suitable evaluation device see Requirements and connection to evaluation devices 10 The following is deemed improper...

Page 6: ...quipment devices systems plant and machinery in accordance with the general standards and guidelines for safety technology It is the company s responsibility only to employ personnel who Are familiar...

Page 7: ...ntil you are just about to connect the unit This will prevent potential contamination Unit features The actuator PSEN 2 2 20 belongs to the safety switch Coded actuator Safety switch with 4 pin M8 mal...

Page 8: ...or Safety switch Magnet 1 2 3 4 Operating distances Sao So Sr Sar mm Somin On Off Legend Sao Assured operating distance Somin Min operating distance Sar Assured release distance The offset independent...

Page 9: ...g Information given in the Technical details 15 must be followed Calculation of the max cable length lmax in the input circuit Rlmax Ri Rl km Imax Rlmax Max overall cable resistance see evaluation dev...

Page 10: ...PNOZelog for safety gate monitoring PNOZ e3 1p PNOZ e3vp PNOZ e5 13p PNOZmulti for safety gate monitoring Configure the switch in the PNOZmulti Configurator with switch type 2 PSS for safety gate moni...

Page 11: ...ock INFORMATION Risk time in accordance with DIN EN 60947 5 3 The risk time is made up of the reaction time of the sensor see Technical details 15 and the processing and delay times of the evaluation...

Page 12: ...CAUTION Possible loss of the safety function by changing the release distance Sar with non flush installation Installing the safety switch non flush within electrically or magnetically con ductive mat...

Page 13: ...roximity switch design 4 and with level of coding Low Alignment errors of the guard must not adversely affect the safety function of the guard The assured operating distance Sao and the assured releas...

Page 14: ...tated operating distances see Technical details 15 only apply when the safety switch and actuator are installed according to the specifications Installation 12 Operating distances may deviate if other...

Page 15: ...2 Nib at the actuator to prevent is from twisting Technical details General Approvals CE EAC Eurasian ECOLAB T V cULus Listed Sensor s mode of operation Magnetic Coding level in accordance with EN ISO...

Page 16: ...ration In accordance with the standard EN 60947 5 2 Frequency 10 55 Hz Amplitude 1 mm Shock stress Acceleration 30g Duration 11 ms Airgap creepage Pollution degree 3 Rated insulation voltage 25 V Rate...

Page 17: ...safety related characteristic data in order to achieve the required safety level for your plant machine Safety characteristic data B10d in accordance with EN ISO 13849 1 2015 and EN 62061 2 000 000 TM...

Page 18: ...d 4 pin 10 m 533 130 PSEN Kabel Winkel cable straightplug10m Female connector M8 straight 4 pin 10 m 533 131 PSEN Kabel Winkel cable angleplug 3m Female connector M8 angled 4 pin 30 m 533 140 PSEN Kab...

Page 19: ...DP67 F 8DI ION Decentralised input module IP67 for PNOZmulti 773 600 EC declaration of conformity This product these products meet the requirements of the directive 2006 42 EC for ma chinery of the Eu...

Page 20: ...T p the spirit of safety are registered and protected trademarks of Pilz GmbH Co KG in some countries We would point out that product features may vary from the details stated in this document dependi...

Reviews: