Change of Tooth Form - Contour 

 

 Turn the flange /32/ clockwise towards the cam /22/ (when looking from the front) to 
change the tooth shape grinding: 

 

 

5.2 Grinding Machine Preparation and Adjustment  

 

Set the grinding machine in horizontal position. Eliminate any unevenness by means of 
adjusting feet. If you use the base, screw the grinding machine to the base. 

 

If cooling is used (option), connect the pump hose to the 1/4” cock and fit the discharge 
hose on the socket, inserting the free end into the collecting vessel. Connect the pump to 
the control box. 
 
Fit the saw band supporting arms with adjusting shifters on the pins of the grinding 
machine frame and tighten with sleeves. Set the adjustable shifters according to the saw 
band size. 

 

CAUTION!!! Carry out the items 1-6 while the  
machine is at standstill and the main switch  
locked. 

 

 

1. 

Raise the grinding arm /1/, raise the feeder arm /24/, unscrew the saw band cover 

/15/. Depressing the plastic pin /20/, loosen the saw band guide /3/ and insert the saw 
band. Screw on the saw band cover /15/ again. 
2. 

Adjust the saw band height with screws /4/ so that the tooth gullet is approx. 2 mm 

above the upper guide surface /3/. Concurrently, the saw band must be guided in parallel 
to the upper guide surface /3/. 

 

3. 

If necessary, set the guides /19/ on the supporting arms /18/ so that the saw band 
is supported at all supporting points. 

4. 

Adjust the screws /6/ so that the saw band may move easily and be at the same 

time sufficiently held in the desired position. 
5. 

Loosen the screw /7/ to set a correct tooth face angle. Tighten the screw /7/ after 

setting. 
6. 

Lower the grinding arm /1/. 

7. 

Shape the grinding wheel with a dressing diamond; a new grinding wheel should be 
shaped according to the figure below: 

 

 

 

 

Summary of Contents for FORESTOR OR 50

Page 1: ..._______________________________________________________________________________ 1 of 19 Navod obsl OR 50 F _2006 08 01_EN doc INSTRUCTION MANUAL SEMI AUTOMATIC BAND SAW GRINDING MACHINE OR 50...

Page 2: ...18b 619 00 Brno declare hereby on our own exclusive responsibility that the machine complies with the EU 89 392 Guidelines for Machines as amended by the EU 91 368 and 93 44 Guidelines and with EN 180...

Page 3: ...ge corresponding to that mentioned in the instruction manual The guarantee does not apply to Violent and mechanical damage of the machine caused by interference of the user or other persons Unavoidabl...

Page 4: ...tion about the PILOUS band saw grinding machine and the possibilities of use as directed The instruction manual contains important instructions on a safe adequate and economically efficient operation...

Page 5: ...instruction manual with safety symbols danger spot signs Danger spot Proceed with maximum caution Dangerous voltage Use goggles Use protective gloves when handling the saw band 0 2 Requirements Concer...

Page 6: ...hutdown is done by the TOTAL STOP push button For putting the machine into operation again unlock the push button by turning it manually Manual cleaning removal of waste e g sawdust wood chips bark ar...

Page 7: ...not adequate to the purpose The manufacturer is not responsible for damages due to such a use The user himself has to bear the risk The use complying with the purpose includes also observing the opera...

Page 8: ...In temperatures below 5 C the conventional coolants should be replaced by coolants designed for respective temperatures 2 3 Connection to Energy Supplies Connect the supply cable to a protected 6A so...

Page 9: ...2P 230V AC Kuhnke R15046 Patina for relay RP Kuhnke V40101 Bushing PG 9 Bimed V40102 Bushing PG 11 Bimed V40328 Nut for bushing PG 9 Bimed V40329 Nut for bushing PG 11 Bimed V0506 Line wire CYA 1 5 sc...

Page 10: ...L STOP OR 50 P i pr ci na stroji pou vejte ochrann pom cky Use protective means while working on the machine Bei Arbeit an der Machine Unfallverh tungsmittel tragen V m na pilov ho p su a brusn ho kot...

Page 11: ...n any performance increase either just the life of the overloaded and overheated saw band will be shorter A good maintenance of the band is vital for the sawing quality Inaccurate cuts and slow sawing...

Page 12: ...life of the tool If there are suddenly bad sawing results or if the saw bands break more frequently it is usually difficult to find out the reason The most frequent reason for breaks is wrong handling...

Page 13: ...ng band saws in semi automatic cycle The change of pitch and the shape of the sharpened teeth are made manually The grinding disk and the saw band shift are driven by electric motors The grinding mach...

Page 14: ..._______________________________________________________________________________ 14 of 19 Navod obsl OR 50 F _2006 08 01_EN doc COMPONENT SPECIFICATION 0 0 I I...

Page 15: ...band holding plate 4 Setting screws of saw band width 5 Lock nut 6 Holding plate screws 7 Tooth face angle setting screw 8 Setting screw of tooth material removal 9 Setting screw of tooth face removal...

Page 16: ...to the left when looking from the front the tooth depth increases by moving to the right the tooth depth decreases and the steepness of the tooth back surface changes at the same time deeper identical...

Page 17: ...shifters according to the saw band size CAUTION Carry out the items 1 6 while the machine is at standstill and the main switch locked 1 Raise the grinding arm 1 raise the feeder arm 24 unscrew the saw...

Page 18: ...screw 9 to the right the shifter shifts back to the left the shifter shifts forward 9 If the tooth profile does not comply with the desired form choose another lever recess 11 for the screw 8 Should...

Page 19: ...just the screws 33 to allow the crank 10 to be turned by hand and the saw band to be moved when the el band feed is switched on Carry out the adjustment while the machine is at standstill 5 3 Grinding...

Page 20: ...ions concerning lubrication Current maintenance of the grinding machine should be always done daily after finishing the work Remove grinding dust from the protective shield and the grinding disk cover...