3.4. Nameplate
The data are only illustrative
MANUFACTURER
MANUFACTURER’S ADRESS
MACHINE MODEL
SERIAL NUMBER
TOTAL WATTAGE
OPERATING VOLTAGE
YEAR OF MANUFACTURE
MACHINE WEIGHT
RATED CURRENT
CONTROL VOLTAGE
Pilous-pásové pily, spol. s r.o.
Producer
Železná 9, 619 00 Brno, CZ
Address
Model
Serial No.
P
U
Year
I
3.2.
Machine installation
Protect the machine against humidity, rain and dust!
The machine may be operated in the ambient temperature b 5° and + 40°C. The average air temperature must not
35°C within 24 hours. In temperatures below + 5°C the conventional coolants should be replaced by coolants designed for such
temperatures.
3.3.
Connection to the mains
Such operations must be carried out only by persons with electrician qualifications!
Make sure that the grid voltage, the voltage protection and the connection voltage comply with the power requirements specified in
the point 2. Technical parameters. Connect the power cable to a protected
16A
socket, in case of direct connection to the mains it is
necessary to fit the supply with a lockable master switch. In machines with a 230V single-phase motor the 230V plug is installed.
When connecting
V400
(with a three-phase 400V motor) machines to the mains (3 NPe, 50 Hz, 400 V, TN-S), mind the colour coding
of wires carefully:
L1
brown
,
L2
black,
L3
gray
,
N
blue,
PE
yellow-brown.
Improper connection of the neutral or PE wires may
lead to damage of the electrical equipment or to and electric shock!
If the motor rotates in an incorrect direction, swap the
conductors
L1
brown
,
L2
black on the junction box.
Failure to observe the aforementioned may lead to incorrect rotation of the bandsaw and the coolant pump.
Danger: Damage to the machine!