background image

 

 

 

 

 

 

 

 
 
 
 
 
 
 
 
 

The  information  in  this  publication  is  provided  for  reference  only.  All 
information  contained  in  this  publication  is  believed  to  be  correct  and 
complete. PIKE Technologies, Inc. shall not be liable for errors contained herein 
nor for incidental or consequential damages in connection with the furnishing, 
performance, or use of this material. All product specifications, as well as the 
information contained in this publication, are subject to change without notice. 
This publication may contain or reference information and products protected 
by  copyrights  or  patents  and  does  not  convey  any  license  under  the  patent 
rights of PIKE Technologies, Inc. nor the rights of others. PIKE Technologies, Inc. 
does  not  assume  any  liability  arising  out  of  any  infringements  of  patents  or 
other rights of third parties. 
This  document  contains  confidential  or  proprietary  information  of  PIKE 
Technologies,  Inc.  Neither  this  document  nor  the  information  herein  is  to  be 
reproduced, distributed, used or disclosed, either in whole or in part, except as 
specifically authorized by PIKE Technologies, Inc. 
PIKE  Technologies,  Inc.  makes  no  warranty  of  any  kind  with  regard  to  this 
material including, but not limited to, the implied warranties of merchantability 
and fitness for a particular purpose. 
Copyright 1991-2019 by PIKE Technologies, Inc., Madison, WI 53719. Printed in 
the  United  States  of  America.  All  world  rights  reserved.  No  part  of  this 
publication may be stored in a retrieval system, transmitted, or reproduced in 
any  way,  including  but  not  limited  to,  photocopy,  photograph,  magnetic  or 
other record, without the prior written permission of PIKE Technologies, Inc. 
 
Address Comments to: 
 
PIKE Technologies, Inc. 
6125 Cottonwood Drive 
Madison, WI 53719 
 
Phone   

(608) 274-2721 

Fax 

 

(608) 274-0103 

E-mail   

[email protected] 

Web Site 

www.piketech.com 

 

 

 

 

Aug. 27, 2019 

Summary of Contents for MIRacle

Page 1: ...Digital Force Adapter for High Pressure Clamp Installation and User Guide...

Page 2: ...cument contains confidential or proprietary information of PIKE Technologies Inc Neither this document nor the information herein is to be reproduced distributed used or disclosed either in whole or i...

Page 3: ...lation for MIRacle 3 Installation for GladiATR or GladiATR Vision 5 Digital Force Adapter Usage 8 Choosing a Press Tip 8 Clamp Operation 9 Zero Adjustment of Digital Force Adapter 9 Application 10 Spe...

Page 4: ......

Page 5: ...he High Pressure Clamp of either the MIRacle or GladiATR It consists of an embedded load cell which exhibits high linearity and exceptional reproducibility To accommodate various sample types the adap...

Page 6: ...e contact PIKE Technologies Inc immediately if any parts have been omitted Packing List Manual PN 350 007660 MIRacle GladiATR Load Cell Assembly with Tip LCD Monitor Quantity 1 Quantity 1 Quantity 1 P...

Page 7: ...clarity Installation for MIRacle 1 Remove the press tip rod from the MIRacle High Pressure Clamp by unscrewing the rod from the top of the horizontal clamp arm 2 Hold the digital force adapter assembl...

Page 8: ...ll it 4 Using the provided plastic hooks secure the cord from the load cell assembly along the horizontal arm of the clamp Place the load cell cord into the eye of the hook and snap the hook closed Re...

Page 9: ...is not connected to the LCD monitor prior to applying power erroneous readings are displayed 7 Choose an appropriate electrical outlet adapter and attach it to the power cord Plug the power cord into...

Page 10: ...tip until finger tight Exhibit care not to excessively twist the cord attached to the load cell assembly To minimize cord twisting allow the cord to hang vertically during installation 4 To reinstall...

Page 11: ...rtion of the clamp 7 Insert the connector of the load cell assembly and the power cord into the back of the LCD monitor The appropriate location of each connector is clearly labeled If the load cell i...

Page 12: ...to the crystal surface This tip allows for better positioning and optimal contact of thin materials with the crystal surface The swivel tip is used with irregularly shaped samples films and semi rigid...

Page 13: ...he control knob turning clockwise until the desired pressure shown on the digital LCD monitor is achieved 4 Collect the sample spectrum Zero Adjustment of Digital Force Adapter The Digital Force Adapt...

Page 14: ...e Adapter Spectra were collected at two force settings 10 and 20 kgf The results show band intensity increases with increasing pressure Using the Digital Force Adapter provides control over applied fo...

Page 15: ...just screw located on the right side of the LCD monitor Service and Repairs For service and repairs please contact PIKE Technologies Inc to obtain a Returned Merchandise Authorization RMA number When...

Page 16: ...wheeled bin is a clear reminder that the product must NOT be disposed with household waste It is the responsibility of the buyer to discard the product in accordance with Federal regional and local en...

Reviews: