PRESSURE & POWER ALERT
Screen has five different pages which can be changed by pressing the INFO switch.
LCD SCREEN—DEFAULT SETUP
The first page of the LCD screen shows the pressure from both sensors. This makes it possible to monitor the liner
pressure at the same time as adjusting it. The pressure is shown in kilopascals (kPa). Along with showing the pressu-
res, the first page also shows if the power alarm is disabled or enabled.
10 kPa = 0.1 Bar, 100 kPa = 1.0 Bar, 10 kPa = 1.45 psi
PRESSURE ALARM LIMITS
The second page of the LCD screen shows the low and high limits of the pressure alarms. The limits can be chosen
individually for both sensors. The limits work intuitively: if the pressure drops below the low limit, or raises above the
high limit, alert messages will be sent.
The default limits are 35 kPa (5.07 psi) for low limit and 85 kPa (12.3 psi) for high limit.
Pressure alarm limits can be changed at any time. Look at the section:
Changing Parameters.
Line
Function
Pressure#1: 0kPa
Pressure data from sensor 1
Pressure#2: 0kPa
Pressure data from sensor 2
Power alarm enabled/disabled
Status of the power alarm
Line
Explanation
L1:
Pressure low limit from sensor 1
L2:
Pressure low limit from sensor 2
Line
Explanation
H1:
Pressure high limit from sensor 1
H2:
Pressure high limit from sensor 2