15
SMART MIXER TROUBLESHOOTING GUIDE
SYMPTOM
CAUSE
REMEDY
Motor does not
start.
Trigger not depressed
Discharged battery
Speed setting too low
Battery pack not fully inserted.
Cartridge fully dispensed (dispenser shuts off
automatically)
Press trigger.
Use charger to recharge battery.
Increase speed setting
Remove and reinstall battery pack.
Remove and replace cartridge.
Motor stops sud-
denly while running.
“
Dose
”
time elapsed
Battery pack not fully inserted.
Cartridge fully dispensed (dispenser shuts off
automatically)
Release trigger, increase
“
dose
”,
press trigger.
Remove and reinstall battery pack.
Remove and replace cartridge.
Motor stops gra-
dually or slows
down.
Discharged battery
Speed setting too low
Use charger to recharge battery.
Increase speed setting
Motor runs, but
resin is not being
dispensed.
Clutch open
Cartridge tip not removed
Resin too cold.
Cured resin clogging mixing tube
Cartridge failure (blow by)
Close clutch.
Remove tip.
Warm the resin.
Replace mixing nozzle (mixing tube).
Remove cartridge. Clean pistons and teeth. Install
new cartridge.
Resin is dispensed
very slowly
Discharged Battery
Speed setting too low
Resin too cold.
Cured resin clogging mixing tube
Cartridge failure (blow by)
Use charger to recharge battery.
Increase speed setting
Warm the resin.
Replace mixing nozzle (mixing tube).
Remove cartridge. Clean pistons and teeth. Install
new cartridge.
Dispensed resin is
not uniformly
mixed.
Resin too cold.
Cured resin in mixing nozzle
Cartridge failure (blow by)
Warm the resin.
Replace mixing nozzle (mixing tube).
Remove cartridge. Clean pistons and teeth. Install
new cartridge.
Rack handle is diffi-
cult to push or pull.
Clutch closed
Resin built up on rack
teeth
Open clutch
Remove cartridge. Clean pistons
and teeth. Install new cartridge.
TROUBLESHOOTING GUIDE