background image

Page 7.3

MATRIX MODULE  40-510/511/512/513

pickering

SECTION 7 - MAINTENANCE INFORMATION

Figure 7.2 - Matrix Module 40-511-021/022:Component Layout

U1

U2

U3

U4

U6

U7

U8

U10

U11

U12

U13

U14

U9

R1
R2

R5
R6
R7
R8
R9

R10
R11
R12
R13
R14

C1

C2

+

+

R4

C3

C4

C5

C6

C7

C8

C9

C10

C11

C12

C13

C15

C16

C14

C17

C18

C19

C20

C21

C22

C23

C24

pickering

1

C26

U5

R3

R15
R16

U15

U16

U17

U18

U20

spare relays

RL97

RL98

200r0

08/98

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

Lk1

Lk3

Lk4

Lk5

Lk6

Lk7

Lk8

A

B

C

D

1

2

3

4

5

6

7

8
9

10

11

12

13

14
15

16

17

18

19

20

21

22
23

24

C25

C26

C27

C28

C29

C30

Lk2

U19

J2

J1

A1

B1

C1

D1

A2

B2

C2

D2

A3

B3

C3

D3

A4

B4

C4

D4

A5

B5

C5

D5

A6

B6

C6

D6

A7

B7

C7

D7

A8

B8

C8

D8

A9

B9

C9

D9

A10

B10

C10

D10

A11

B11

C11

D11

A12

B12

C12

D12

A13

B13

C13

D13

A14

B14

C14

D14

A15

B15

C15

D15

A16

B16

C16

D16

A17

B17

C17

D17

A18

B18

C18

D18

A19

B19

C19

D19

A20

B20

C20

D20

A21

B21

C21

D21

A22

B22

C22

D22

A23

B23

C23

D23

A24

B24

C24

D24

SPARE

SPARE

TABLE 7.2 - Dual 12 x 4 Matrix 40-511-021: Relay Numbering

Matrix Module 40-511-021: Bank 1 Signal paths (with relay energised)

 

Relay 

Position

Relay 

Number

Crosspoint

Relay 

Position

Relay 

Number

Crosspoint

Relay 

Position

Relay 

Number

Crosspoint

Relay 

Position

Relay 

Number

Crosspoint

A1

1

X101,Y101

B1

13

X101,Y102

C1

25

X101,Y103

D1

37

X101,Y104

A2

2

X102,Y101

B2

14

X102,Y102

C2

26

X102,Y103

D2

38

X102,Y104

A3

3

X103,Y101

B3

15

X103,Y102

C3

27

X103,Y103

D3

39

X103,Y104

A4

4

X104,Y101

B4

16

X104,Y102

C4

28

X104,Y103

D4

40

X104,Y104

A5

5

X105,Y101

B5

17

X105,Y102

C5

29

X105,Y103

D5

41

X105,Y104

A6

6

X106,Y101

B6

18

X106,Y102

C6

30

X106,Y103

D6

42

X106,Y104

A7

7

X107,Y101

B7

19

X107,Y102

C7

31

X107,Y103

D7

43

X107,Y104

A8

8

X108,Y101

B8

20

X108,Y102

C8

32

X108,Y103

D8

44

X108,Y104

A9

9

X109,Y101

B9

21

X109,Y102

C9

33

X109,Y103

D9

45

X109,Y104

A10

10

X110,Y101

B10

22

X110,Y102

C10

34

X110,Y103

D10

46

X110,Y104

A11

11

X111,Y101

B11

23

X111,Y102

C11

35

X111,Y103

D11

47

X111,Y104

A12

12

X112,Y101

B12

24

X112,Y102

C12

36

X112,Y103

D12

48

X112,Y104

Matrix Module 40-511-021: Bank 2 Signal paths (with relay energised)

 

Relay 

Position

Relay 

Number

Crosspoint

Relay 

Position

Relay 

Number

Crosspoint

Relay 

Position

Relay 

Number

Crosspoint

Relay 

Position

Relay 

Number

Crosspoint

A13

1

X201,Y201

B13

13

X201,Y202

C13

25

X201,Y203

D13

37

X201,Y204

A14

2

X202,Y201

B14

14

X202,Y202

C14

26

X202,Y203

D14

38

X202,Y204

A15

3

X203,Y201

B15

15

X203,Y202

C15

27

X203,Y203

D15

39

X203,Y204

A16

4

X204,Y201

B16

16

X204,Y202

C16

28

X204,Y203

D16

40

X204,Y204

A17

5

X205,Y201

B17

17

X205,Y202

C17

29

X205,Y203

D17

41

X205,Y204

A18

6

X206,Y201

B18

18

X206,Y202

C18

30

X206,Y203

D18

42

X206,Y204

A19

7

X207,Y201

B19

19

X207,Y202

C19

31

X207,Y203

D19

43

X207,Y204

A20

8

X208,Y201

B20

20

X208,Y202

C20

32

X208,Y203

D20

44

X208,Y204

A21

9

X209,Y201

B21

21

X209,Y202

C21

33

X209,Y203

D21

45

X209,Y204

A22

10

X210,Y201

B22

22

X210,Y202

C22

34

X210,Y203

D22

46

X210,Y204

A23

11

X211,Y201

B23

23

X211,Y202

C23

35

X211,Y203

D23

47

X211,Y204

A24

12

X212,Y201

B24

24

X212,Y202

C24

36

X212,Y203

D24

48

X212,Y204

Summary of Contents for PXI 40-510

Page 1: ...Page 1 MATRIX MODULE 40 510 511 512 513 pickering Issue 8 2 March 2017 User Manual Matrix Module Model No 40 510 511 512 513 pickeringtest com pickering...

Page 2: ...KERING INTERFACES ALL RIGHTS RESERVED No part of this publication may be reproduced transmitted transcribed translated or stored in any form or by any means without the written permission of Pickering...

Page 3: ...14001 Pickering Interfaces strives to fulfil all relevant environmental laws and regulations and reduce wastes and releases to the environment Pickering Interfaces aims to design and operate products...

Page 4: ...azards arising from dangerous voltages WARNING CAUTION An appropriate safety instruction should be followed or caution to a potential hazard exists Refer to the relevant instructions detailed within t...

Page 5: ...ion 3 2 Testing Operation 3 3 Section 4 Programming Guide 4 1 Programming Options For Pickering PXI Cards 4 1 Module Architecture 40 510 4 3 Module Architecture 40 511 4 4 Module Architecture 40 512 4...

Page 6: ...Page VI MATRIX MODULE 40 510 511 512 513 pickering THIS PAGE INTENTIONALLY BLANK...

Page 7: ...hese devices 1 Persons removing sub assemblies from equipment using these devices must be earthed by a wrist strap and a resistor at the point provided on the equipment 2 Soldering irons used during t...

Page 8: ...Page VIII MATRIX MODULE 40 510 511 512 513 pickering THIS PAGE INTENTIONALLY BLANK...

Page 9: ...10 series modules are fitted with Reed Relays Ruthenium sputtered type these offer very long life with good low level switching performance and excellent contact resistance stability Spare Reed Relays...

Page 10: ...PXI CompactPCI card Module weight 280g 40 513 021 260g 40 513 022 3D models for all versions in a variety of popular file formats are available on request Connectors PXI bus via 32 bit P1 J1 backplane...

Page 11: ...xpress chassis Compatible with Pickering Interfaces LXI Modular Chassis For information on driving your switching solution in an LXI environment refer to the LXI Product Guide PXI CompactPCI Complianc...

Page 12: ...Page 1 4 MATRIX MODULE 40 510 511 512 513 pickering SECTION 1 TECHNICAL SPECIFICATION THIS PAGE INTENTIONALLY BLANK...

Page 13: ...wo pole depending on the module type are energised via control signals from storage registers U9 to U20 The storage registers are addressed by PCI bridge U1 to output the required signal Module config...

Page 14: ...Page 2 2 MATRIX MODULE 40 510 511 512 513 pickering SECTION 2 TECHNICAL DESCRIPTION THIS PAGE INTENTIONALLY BLANK...

Page 15: ...ative to any other equipment the module s will connect with Ensure the chassis is not connected to the electrical supply 3 Ensure that the designated area for the chassis containing the module is of f...

Page 16: ...to page VII Ensure that there is adequate ventilation The module should be installed in accordance with the following procedure 1 Ensure that the system is turned OFF but still connected to mains so...

Page 17: ...Panel GSFP using the desktop icon or via the Start menu Start Menu Pickering Interfaces Ltd General Soft Front Panel A selector panel will appear listing all installed Pickering PCI PXI or LXI switch...

Page 18: ...Page 3 4 MATRIX MODULE 40 510 511 512 513 pickering SECTION 3 INSTALLATION THIS PAGE INTENTIONALLY BLANK...

Page 19: ...es fully hyperlinked for easy access both pipx40 and Pilpxi documents are included in the Pipx40vpp software installation IVI Driver for Windows pi40iv The pi40iv IVI Interchangeable Virtual Instrumen...

Page 20: ...erface options not available in PXI NET A NET native driver is also available Once again this may be used for both LXI and PXI card control SOAP Pickering LXI products include a SOAP interface which i...

Page 21: ...1 20 2 8 X8 to Y2 1 21 2 9 X9 to Y2 1 22 2 10 X10 to Y2 1 23 2 11 X11 to Y2 1 24 2 12 X12 to Y2 1 25 3 1 X1 to Y3 1 26 3 2 X2 to Y3 1 27 3 3 X3 to Y3 1 28 3 4 X4 to Y3 1 29 3 5 X5 to Y3 1 30 3 6 X6 t...

Page 22: ...1 40 4 4 X104 to Y104 1 41 4 5 X105 to Y104 1 42 4 6 X106 to Y104 1 43 4 7 X107 to Y104 1 44 4 8 X108 to Y104 1 45 4 9 X109 to Y104 1 46 4 10 X110 to Y104 1 47 4 11 X111 to Y104 1 48 4 12 X112 to Y10...

Page 23: ...X10 to Y4 1 47 4 11 X11 to Y4 1 48 4 12 X12 to Y4 The 40 512 021 is an array of 96 single pole relays and the 40 512 022 an array of 96 double pole relays In the default state all relays are open circ...

Page 24: ...23 X23 to Y2 1 48 2 24 X24 to Y2 The 40 513 021 is an array of 96 single pole relays and the 40 513 022 an array of 96 double pole relays In the default state all relays are open circuit Energising a...

Page 25: ...hole matrix of a single matrix module or bank 1 of a dual matrix module If bank 2 of a dual matrix were to be selected sub unit 2 would be specified Using PILPXI To operate a relay the user could use...

Page 26: ...the normal X Y labelling tags Note the following example is for bank 1 of a dual matrix Bank 1 is identified as A bank 2 would be identified as B and a single matrix would have no letter identifier pi...

Page 27: ...GND 68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1...

Page 28: ...2 X203 2 X204 2 X205 2 X206 2 X207 2 X208 2 X209 2 X210 2 X211 2 X212 2 Y201 2 Y202 2 Y203 2 Y204 2 GND 68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37...

Page 29: ...2 X5 2 X6 2 X7 2 X8 2 X9 2 X10 2 X11 2 X12 2 Y1 2 Y2 2 Y3 2 Y4 2 GND Y5 2 Y6 2 Y7 2 Y8 2 GND 68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33...

Page 30: ...Y4 2 GND X13 2 X14 2 X15 2 X16 2 X17 2 X18 2 X19 2 X20 2 X21 2 X22 2 X23 2 X24 2 Y1 2 Y2 2 Y3 2 Y4 2 GND 68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37...

Page 31: ...ystem s PCI configuration highlighting any potential configuration problems Specific details of all installed Pickering switch cards are included All the installed Pickering switch cards should be lis...

Page 32: ...MATRIX MODULE 40 510 511 512 513 Page 6 2 pickering SECTION 6 TROUBLE SHOOTING THIS PAGE INTENTIONALLY BLANK...

Page 33: ...uch as the 60 102B and 60 103B no module software update is required If the module was introduced after the LXI chassis was manufactured the module may not be recognized in this case the chassis firmw...

Page 34: ...0 C10 D10 A11 B11 C11 D11 A12 B12 C12 D12 SPARE SPARE TABLE 7 1 Single 12 x 4 Matrix 40 510 021 Relay Numbering Matrix Module 40 510 021 Signal paths with relay energised Relay Position Relay Number C...

Page 35: ...X103 Y104 A4 4 X104 Y101 B4 16 X104 Y102 C4 28 X104 Y103 D4 40 X104 Y104 A5 5 X105 Y101 B5 17 X105 Y102 C5 29 X105 Y103 D5 41 X105 Y104 A6 6 X106 Y101 B6 18 X106 Y102 C6 30 X106 Y103 D6 42 X106 Y104 A...

Page 36: ...Y1 B1 13 X1 Y2 C1 25 X1 Y3 D1 37 X1 Y4 A2 2 X2 Y1 B2 14 X2 Y2 C2 26 X2 Y3 D2 38 X2 Y4 A3 3 X3 Y1 B3 15 X3 Y2 C3 27 X3 Y3 D3 39 X3 Y4 A4 4 X4 Y1 B4 16 X4 Y2 C4 28 X4 Y3 D4 40 X4 Y4 A5 5 X5 Y1 B5 17 X5...

Page 37: ...49 X1 Y3 D1 73 X1 Y4 A2 2 X2 Y1 B2 26 X2 Y2 C2 50 X2 Y3 D2 74 X2 Y4 A3 3 X3 Y1 B3 27 X3 Y2 C3 51 X3 Y3 D3 75 X3 Y4 A4 4 X4 Y1 B4 28 X4 Y2 C4 52 X4 Y3 D4 76 X4 Y4 A5 5 X5 Y1 B5 29 X5 Y2 C5 53 X5 Y3 D5...

Page 38: ...Page 7 6 MATRIX MODULE 40 510 511 512 513 pickering SECTION 7 MAINTENANCE INFORMATION Figure 7 5 Matrix Module 40 513 021...

Reviews: