2
All parts (
①
according to the contrary direction
to installation.
3
Juice outlet lid can be freely
detached or installed.
4
If there are pomaces stay in
pomace outlet, withdraw the
sealing gum from the pomace
outlet groove and rinse it with
water, then insert it back to the
groove
Common failure
Cause analysis
Solution
After power
connecting,
switch it on and
the Juicer doesn’t
work.
1.Center ring was not
installed in place.
2. Top cap was not
installed in place.
3. Microswitch is broken.
1. Put the center ring in
place.
2. Put the top cap in
place.
3. Replace top cap.
4. Put all parts in place.
13
Chapter VII. Trouble Shooting
1
2
3
4