DT2010218-04
7.10 REPLACING ThE REMOTE CONTROL bATTERIES
Slide the cover off the back of the remote control and replace the batteries
with new ones ensuring that the (+) and (–) directions are correct.
The batteries must be of the type
AAA (LR03) 1.5V
.
a
Rechargeable batteries are unsuitable for the remote control as
they do not guarantee sufficient voltage for correct operation.
Replace the back cover on the remote control.
The writing shown to the side appears on the display of the remote control.
A feedback procedure between the remote control and the receiver starts
automatically.
After a few seconds the initial display returns.
In other words, stove status prior to changing the batteries will be
displayed.
E.g.: if the stove was shut down, the display will appear as shown to the
side.
The new batteries must be of the same type as above; failure to comply
with these instructions could cause a risk of explosion.
The old batteries must be disposed of properly in compliance with
the applicable laws in force.
T E S T H W 4
I N I Z I A L E
V E R 4
O F F
0 9 : 5 3 2 0
°C
1
Fig. 66
DT2010218-00
A
Fig. 67
Fig. 68
DT2012390-00
7.11 CLEANING ThE FANS
a
Any cleaning or maintenance work must be carried out after
the CURRENT HAS BEEN SWITCHED OFF.
The stove is fitted with fans (smoke extractor and room) positioned at
the bottom and rear of the stove.
Any build-up of dust or ash on the blades can unbalance them resulting
in noise during operation.
It is necessary to have the fans cleaned at least once a year.
a
Since such a procedure involves dismantling certain parts of
the stove, have the cleaning carried out only by a Piazzetta
Service Centre or other qualified persons.
To access the room fan/s, remove the side ceramic panel/s (see
instructions in CLADDING booklet).
Remove the cover plate [A] screwed onto the external housing by
loosening the screws. (Fig. 67)
Clean the fan/s (Fig. 68) then refit the cover plate [A] and the side
ceramic panel/s.
H07026300 / DT2000786 – 00
51
English
DT2033447-00