![Piazzetta P958 Instructions For Installation, Use And Maintenance Manual Download Page 29](http://html1.mh-extra.com/html/piazzetta/p958/p958_instructions-for-installation-use-and-maintenance-manual_1554808029.webp)
RESTARTING DURING THE SHUTDOWN PHASE
Description
Display
SITUATION 1
The stove is in the shutdown phase and the readout CLEANING BRAZIER is on the display.
The stove is restarted by the user pressing the ON/OFF key.
The readout “
WAIT COOLING
” appears on the display.
This means that you must wait for the necessary cooling times.
When the stove has cooled down sufficiently, the new ignition cycle will restart automatically from
the control phase.
W A I T
C O O L I N G
1 2 : 0 0 2 2
.c
1
SITUATION 2
The stove is in the shutdown phase and the OFF status has just appeared on the display.
The stove is restarted by the user pressing the ON/OFF key.
The readout “
STAND-BY OFF
” appears on the display.
This means that the stove is still warm and you must wait for the necessary cooling times.
When the stove has cooled down sufficiently, the new ignition cycle will restart automatically from
the control phase.
S T A N D - B Y
O F F
1 2 : 0 0 2 2
.c
1
DT2012312-00
INTERRUPTION OF POWER SUPPLY
Description
Display
If there is a blackout while the stove is in operation, there are two possibilities of procedure according
to stove set-up:
-
blackout without timer thermostat settings;
-
blackout with timer thermostat settings.
Blackout without timer thermostat settings.
When the electricity supply is restored, the appliance restarts automatically.
• The grate cleaning phase activates.
• The fan operates at full speed to allow the stove to cool.
• The automatic stove restart cycle starts (the steps detailed in the ‘
STARTUP
’ phase are repeated
automatically).
• Once the ignition cycle has been completed the stove operates normally at power level 2 with
Multifuoco on 2.
Blackout with timer thermostat settings.
There are 3 possible situations.
- Blackout straddling the time set for ignition: the stove does not restart.
- Blackout straddling the time set for shutdown: the stove restarts when the electricity supply is
restored.
- Blackout within the programmed operating time band: the stove restarts when the electricity supply
is restored.
Restarting is carried out with the same procedure as listed in “
Blackout without timer thermostat
settings
”.
C L E A N I N G
1 2 : 0 0 2 2
.c
1
DT2040061-05
EMERGENCY LIGHTING OF STOVE
Description
Display
If the glow plug is not working, the stove may be lit manually as follows:
- pour a small quantity of pellets into the grate;
- use a lit piece of solid firelighter (not liquid) to ignite the pellets;
- close the door;
- start the stove using the ON/OFF button.
a
This procedure is only to be carried out in an emergency while waiting for the servicing technician to arrive.
DT2040098-00
H07026300 / DT2000786 – 00