SHUTDOWN
Action
Description
Display
Hold the ON/OFF key
down for several
seconds
C L E A N I N G
B R A Z I E R
1 2 : 0 0 2 2
.c
1
Fuel loading stops, while the cooling fan and the extractor fan continue to
operate until the stove has cooled.
• The readout “
PUL
” appears in STOVE STATUS along with the flue gas
temperature.
• See the section on programming.
C L E A N I N G
B R A Z I E R
1 2 : 0 0 2 2
.c
1
a
Never unplug the stove from the power supply at this stage as this could cause internal problems and compromise subsequent
ignition operations.
DT2040060-05
EXTERNAL THERMOSTAT
Action
Description
Display
Stove operation can be regulated by any kind of external room thermostat
connected to the electronic board.
To connect the thermostat, see “
INSTALLING THE EXTERNAL ROOM
THERMOSTAT
”.
Press the
TEMPERATURE
key and
S E T T E M P
R O O M
7
.c
1
select
S E T T E M P
R O O M
7
.c
1
With the stove powered, irrespective of the operating status, set the stove
to the minimum temperature value of 7°C.
Operation of the external thermostat depends on the stove temperature
setting:
- if the set stove temperature is less than the room temperature, the
external thermostat prevails.
- if the set stove temperature is more than the room temperature, the
internal stove thermostat prevails. The external thermostat is disabled.
S E T T E M P
R O O M
7
.c
1
a
The room sensor must be connected. If the room sensor is not connected the appliance does not modulate the power and operates
to user settings.
DT2040059-07
H07026300 / DT2000786 – 00
27