5 Installation
V-273 VC Linear Actuator
MP155E
Version: 1.1.4
23
Attaching the V-273 to the fixed part of the mounting
1.
Align the linear actuator or surface so that the corresponding mounting holes in linear
actuator and surface overlap.
2.
Turn the screws into the mounting holes in the bottom of the underlying surface.
Maximum screw-in depth: 5 mm
Maximum torque: 2.6 Nm
3.
Check that the V-273 is fixed firmly to the surface.
5.4
Connecting the V-273 to the Controller
INFORMATION
The V901B0030 adapter is adapted at the factory to the V-273 to achieve optimal positioning
accuracy. Replacing the adapter or the V-273 leads to an incorrect positioning and may even
lead to oscillations of the servo loop.
When connecting the V-273, pay attention to the assignment of the adapter to the V-273,
which is specified on the label of the adapter.
Requirements
You have read and understood the general notes on installation (p. 17).
The controller is switched off, i.e.,
not
connected to the power supply
Tools and accessories
V901B0030 adapter D-sub 15 (m/f), included in the scope of delivery (p. 11)
Motor cable D-sub 15 (m/f), to be ordered separately
C-413.2xx controller (p. 11)
Connecting the V-273 to the controller
1.
Connect the D-sub 15-pole (f) connector of the adapter to the
Motor &Sensor
socket of
the controller.
2.
Connect the connector of the motor cable to the D-sub 15-pole (f) socket of the
adapter.
3.
Connect the socket of the motor cable to the D-sub 15-pole panel plug (m) of the linear
actuator.
4.
Secure the adapter and motor cable with the integrated screws against unintentional
disconnection from each other or from the controller and the linear actuator.
5.
When the linear actuator has a force sensor with a separate D-sub 15 (m) connector:
Connect the force sensor to the
Motor & Sensor
socket of the C-413 that is still free.