5 Installation
V-273 VC Linear Actuator
MP155E
Version: 1.1.4
19
INFORMATION
If unsuitable cables are used, interference can occur in the signal transmission between the
linear actuator and the controller.
Only use original PI parts to connect the linear actuator to the controller. The maximum
cable length is
1,5 m
.
If you need longer cables, contact our customer service department (p. 35).
INFORMATION
For the positive direction of motion of the runner (X axis), see "Product Details" (p. 8) or the
dimensional drawing in "Dimensions" (p. 40).
5.2
Optional: Changing the Contact Part of the Force Sensor on the
V-273.441
INFORMATION
The mechanical coupling of the runner to a surface is achieved using the contact part of the
force sensor. A contact part made of aluminum and plastic is installed by default.
If you change the contact part, you may have to adapt the parameter settings of the C-413
controller to the changed contact stiffness.
Requirements
The linear actuator is
not
connected to the controller.
Tools and accessories
Suitable contact part with M3 internal thread
Changing the contact part of the force sensor on the V-273.441 model
1.
Manually unscrew the contact part to be changed from the force sensor of the
V-273.441.
2.
Manually screw the new contact part onto the M3 threaded bolt of the force sensor.
Maximum torque: 15 Ncm.