
6 Start-Up and Operation
PL0xx/PDxxx Piezo Actuator
PZ265E
Version: 1.0.0
37
6.2.2
Calculating the Effective Mass
Figure 12: Calculation of the effective mass of a unilaterally clamped piezo stack actuator without load
(left) and with additional load (right).
1.
Determine the mass m of your piezo actuator.
2.
Determine the additional load M.
3.
Calculate the effective mass m
eff
of the unloaded piezo actuator and m
eff
' of the loaded
piezo actuator using the formulas in the figure above.
6.2.3
Calculating the Maximum Operating Frequency of the Loaded Piezo
Actuator
INFORMATION
In the following calculation, the maximum permissible operating temperature of the piezo
actuator is
not
taken into account. During operation without cooling, the maximum operating
temperature may already be exceeded when the operating frequency is still below the limit
value calculated in the following.
For the maximum permissible operating frequency without cooling, see column B of the
table in "Maximum Ratings" (p. 51).