5 Installation
PL0xx/PDxxx Piezo Actuator
PZ265E
Version: 1.0.0
29
5.6
Connecting the PL0xx/PDxxx to the Electronics
The PL0xx/PDxxx piezo actuator is connected to a LEMO socket, a terminal, or soldering pins,
depending on the electronics.
This section describes how the PL0xx/PDxxx piezo actuator is connected with the P-890.xx
coaxial cable to electronics with a single-pole LEMO socket.
If you use a self-made connecting cable instead of the P-890.xx coaxial cable for
connection to a single-pole LEMO socket, observe the relevant standards as well as the
assembly information of the manufacturer of the connector used.
For connection to the electronics with a two-pole LEMO socket, contact our customer
service department (p. 47).
For connection to terminals or solder pins, see the manual of the respective electronics
used (p. 3).
INFORMATION
The models with stranded wires have color-coded wires:
Red stranded wire: Voltage connection (+)
Black stranded wire: Ground (-)
Figure 11: Connection of the PL0xx/PDxxx piezo actuator to the P-890.xx coaxial cable
+
On the piezo actuator (left): Red stranded wire for voltage connection
On the LEMO connector (right): Inner contact for voltage connection
-
On the piezo actuator (left): Black stranded wire for ground
On the LEMO connector (right): Connector housing
S
Cable shield
LEMO
LEMO connector, single-pole
Requirements
You have read and understood the general notes on installation (p. 17).
You have read and understood the user manual of the electronics used.