5 Installation
20
Version: 3.2.0
PZ82E
P-5x7/P-5x8 Positioners
5.3
Mounting the P-5x7/P-5x8
NOTICE
Warping the P-5x7/P-5x8 when mounting onto uneven surfaces!
The P-5x7/P-5x8 could warp if mounted on an uneven surface. Warping reduces the accuracy.
Mount the P-5x7/P-5x8 onto a flat surface. The recommended flatness of the surface is
≤20
µm.
For applications with large temperature fluctuations:
Mount the P-5x7/P-5x8 only onto surfaces that have the same or similar thermal expansion
properties as the P-5x7/P-5x8.
NOTICE
Tensile stress on piezo actuator due to mounting in wrong orientation!
The P-5x7/P-5x8 is intended for mounting in horizontal orientation (standing on a surface, not
suspended). Mounting in other orientations can cause tensile stress that reduces the preload
and destroys the piezo actuator.
If you want to mount the P-5x7/P-5x8 in a different orientation to that intended (e.g.,
vertically or upside down), contact our customer service department (p. 35).
Figure 4: Mounting holes in the base body
Requirements
You have read and understood the general notes on installing (p. 17).
You have provided a suitable surface for fixing the P-5x7/P-5x8:
−
The surface has four threaded holes for M6 screws. Refer to "Dimensions" (p. 42)
for the position and depth required for the holes.
−
The surface flatness is ≤2
0 µm.
−
For applications with large temperature fluctuations: The surface should have the
same thermal expansion properties as the P-5x7/P-5x8 (e.g., surface made of
aluminum).