PI P-2 5 Series User Manual Download Page 16

 

 

3 Product Description 

12 

Version: 1.1.1 

PZ245E 

P-2x5 Piezo Actuator 

3.3

 

Scope of Delivery 

Product no. 

Description 

P-2x5 

Piezo actuator according to order (p. 7) 

000036450 

M4 screw set for protective earth, consisting of: 

 

1 M4x8 flat-head screw with cross recess, ISO 7045 

 

2 safety washers 

 

2 flat washers 

P-202.01 

Shorting plug for high-voltage piezo actuators 

PZ246EK 

Short instructions for "PICA Piezo Actuators 1000 V" 

 

 

3.4

 

Suitable Electronics 

You need electronics to operate a P-2x5. The device is selected depending on the type of 

application. The table below lists the suitable devices. 

Product no. 

Description 

E-421.00 

High-power piezo amplifier module, without housing, 1 channel, 1100 V 

voltage range, 550 W, integrated power supply 

E-470.20 

High-power piezo amplifier, 1 channel, 1100 V voltage range, 550 W, benchtop 

device 

E-471.20 

High-power piezo amplifier, 1 channel, 1100 V voltage range, 550 W, 19'', 

prepared for servo controller and display / PC interface 

E-472.20 

2-channel high-power piezo amplifier, 1100 V voltage range, 550 W, 19" 

E-462.00 

HVPZT Piezo amplifier, 10 to 1000 V, benchtop device 

E-462.OE1 

HVPZT Piezo amplifier module, 10 to 1000 V, OEM Version 

E-464.00 

HVPZT piezo amplifier, 3 channels, 1100 V voltage range, benchtop device 

E-481.00 

PICA high-performance piezo amplifier / controller with energy recovery, 

1100 V voltage range, 2000 W, 19'' 

E-482.00 

PICA high-performance piezo amplifier / controller with energy recovery, 

1050 V, 6 A, 19'' 

Summary of Contents for P-2 5 Series

Page 1: ...iezo actuator P 225 10 20 40 80 Without sensor P 225 10V 20V 40V 80V Without sensor high temperature range and high vacuum P 225 1S 2S 4S 8S With sensor P 225 1SV 2SV 4SV 8SV With sensor high temperat...

Page 2: ...GmbH Co KG Karlsruhe Germany The text photographs and drawings in this manual are protected by copyright With regard thereto Physik Instrumente PI GmbH Co KG retains all the rights Use of said text ph...

Page 3: ...3 2 2 Product Labeling 11 3 3 Scope of Delivery 12 3 4 Suitable Electronics 12 3 5 Accessories 13 3 6 Technical Features 15 3 6 1 PICA Piezo Actuators 15 3 6 2 Strain Gauge Sensors SGS 15 4 Unpacking...

Page 4: ...Specifications 41 10 1 1 Data Table 41 10 1 2 Maximum Ratings 43 10 1 3 Ambient Conditions and Classifications 44 10 2 Dimensions 45 10 2 1 P 2x5 Piezo Actuator 45 10 2 2 P 2x5 with P 177 50 Option Te...

Page 5: ...table safety measures is assumed The latest versions of the user manuals are available for download p 3 on our website 1 2 Symbols and Typographic Conventions The following symbols and typographic con...

Page 6: ...strations can deviate from the actual circumstances Photographic illustrations may also differ and must not be seen as guaranteed properties 1 4 Other Applicable Documents The devices and software too...

Page 7: ...blems occur with downloading Contact our customer service department p 39 Downloading Manuals 1 Open the website www pi ws 2 Search the website for the product number e g P 225 or the product family e...

Page 8: ......

Page 9: ...ded use of the P 2x5 is only possible in a completely mounted and connected state and only in combination with suitable drive or control electronics p 12 available from PI The electronics is not inclu...

Page 10: ...ective earth conductor before restarting Mechanical forces can damage or misalign the P 2x5 Avoid knocks that affect the P 2x5 Do not drop the P 2x5 Avoid torques bending forces and lateral forces on...

Page 11: ...uators that have a customer specific product number due to integrated options Piezo actuators without a sensor Model Description P 225 10 Preloaded high load piezo actuator 15 m 1000 V 12500 N P 225 2...

Page 12: ...d high load piezo actuator 60 m 1000 V 30000 N high temperature vacuum P 235 80V Preloaded high load piezo actuator 120 m 1000 V 30000 N high temperature vacuum P 235 90V Preloaded high load piezo act...

Page 13: ...000 V 12500 N SGS high temperature vacuum P 225 8SV Preloaded high load piezo actuator 120 m 1000 V 12500 N SGS high temperature vacuum P 235 1SV Preloaded high load piezo actuator 15 m 1000 V 30000 N...

Page 14: ...ure 1 Exemplary product view 1 Housing consisting of 1a Base with wrench flats 1b Housing tube Not shown here Optional inlets and outlets for purge air optional water protection 2 Tip with wrench flat...

Page 15: ...h position from the left 1 internal information 2 and 3 year of manufacture 4 to 9 consecutive number Manufacturer s logo Warning sign Pay attention to the manual Old equipment disposal p 51 Country o...

Page 16: ...igh power piezo amplifier module without housing 1 channel 1100 V voltage range 550 W integrated power supply E 470 20 High power piezo amplifier 1 channel 1100 V voltage range 550 W benchtop device E...

Page 17: ...piezo actuator Piezo actuators equipped with these options have a customer specific product number begins with P 2x5K Product no Description P 177 50 PT1000 temperature sensor and purge air connector...

Page 18: ...nnectors 3 m P 892 05 Extension cable for strain gauge sensors LEMO connectors 5 m P 892 10 Extension cable for strain gauge sensors LEMO connectors 10 m P 892 15 Extension cable for strain gauge sens...

Page 19: ...sing The high load capacity and internal preload makes them ideal for applications such as precision manufacturing and active vibration damping 3 6 2 Strain Gauge Sensors SGS Strain gauge sensors deri...

Page 20: ......

Page 21: ...contraction can destroy the piezo actuator Remove the supplied shorting plug from the voltage connection of the piezo actuator only when this is necessary for installation or operation Keep the shorti...

Page 22: ...again by wiping and shrink wrapped twice in vacuum compatible film Touch the piezo actuator only with powder free gloves If necessary wipe the piezo actuator clean after unpacking 1 Unpack the P 2x5 w...

Page 23: ...rcuiting leads to an abrupt contraction of the piezo actuator due to excessively fast discharging Abrupt contraction can destroy the piezo actuator Remove the supplied shorting plug from the voltage c...

Page 24: ...Dimensions section p 45 Do not screw the piezo actuator tight at both ends NOTICE Damage due to unsuitable cables Unsuitable cables can damage the P 2x5 and the electronics Use cables provided by PI o...

Page 25: ...ally The following figures are to help you avoid mounting errors Figure 4 Not tightly screwed at both ends and no angles A Wrong Angular error at the tip B Right Axial loading of the actuator C Wrong...

Page 26: ...on in your application secure the screw connection for the protective earth conductor in a suitable manner e g with conductive liquid adhesive to prevent it from unscrewing by itself There is an M4 ho...

Page 27: ...tective earth conductor 1 If necessary attach a suitable cable lug to the protective earth conductor 2 Use the M4 screw together with the flat and lock washers to attach the cable lug of the protectiv...

Page 28: ...mechanical connections to a load are made possible by optionally available flat or ball tips p 13 Requirements You have read and understood the general notes on installing p 19 The P 2x5 is not conne...

Page 29: ...ze to hold the tip of the P 2x5 in place 2 Fasten the load to the mounting hole in the tip with an M8 screw see Dimensions p 45 3 Remove the open end wrench from the tip 5 6 Optional Connecting the Pu...

Page 30: ...urge air The requirements on purge air quality can generally be met by running compressed air conformant to ISO 8573 1 2010 Particulates Class 2 Humidity Class 4 Temperature at least 3 C above dew poi...

Page 31: ...shock Connect the P 2x5 to a protective earth conductor p 22 before starting Do not remove the protective earth conductor during operation If the protective earth conductor has to be removed temporar...

Page 32: ...to the specifications p 41 Pay attention to the notes in Determining the Operating Parameters p 30 NOTICE Destruction of the piezo actuator due to excessive operating frequencies Excessive operating...

Page 33: ...or p 13 Adjust the operating voltage operating frequency and or operating time so that the maximum operating temperature of the piezo actuator is not exceeded see Ambient Conditions and Classification...

Page 34: ...e operating temperature of the piezo actuator p 44 The greater the operating frequency the operating voltage peak to peak and the capacitance of the piezo actuator the greater the thermal power genera...

Page 35: ...iezo actuator and meff of the loaded piezo actuator with the formulas in the above figure 6 2 3 Calculating the Maximum Operating Frequency of the Loaded Piezo Actuator INFORMATION In the following ca...

Page 36: ...nt frequency of the loaded piezo actuator Hz 6 2 4 Calculating the Forces that Occur During Dynamic Operation Calculate the dynamic forces that act on the piezo actuator during sinusoidal operation wi...

Page 37: ...l capacitance of the piezo actuator For large signal conditions a safety factor of 70 should be added to the small signal capacitance Up p Operating voltage peak to peak V Voltage difference between p...

Page 38: ...be short circuited with the shorting plug p 12 provided Requirements You have read and understood the general notes on installing p 19 Tools and accessories Electronics from PI p 12 Discharging a P 2...

Page 39: ...ead to the destruction of the piezo actuator by electric flashovers Before cleaning the P 2x5 1 Discharge the P 2x5 p 34 2 Disconnect the voltage connection of the P 2x5 from the electronics 3 Connect...

Page 40: ...zo actuator is not used in vacuum If necessary clean the P 2x5 surface with a cloth dampened with a mild cleanser or disinfectant e g isopropyl alcohol Only when the piezo actuator is used in vacuum T...

Page 41: ...s p 13 the E 481 and E 482 electronics evaluate the signal of the temperature sensor 1 Switch off the electronics 2 Wait a few minutes until the piezo actuator has cooled down sufficiently 3 Switch th...

Page 42: ...gly set because for example the load was changed 1 Switch off the servo mode of the corresponding axes immediately 2 Check the servo control parameter settings on the controller 3 Adjust the servo con...

Page 43: ...tion Product and serial numbers of all products in the system Firmware version of the controller if applicable Version of the driver or the software if applicable Operating system on the PC if applica...

Page 44: ......

Page 45: ...10 N m 20 Resonant frequency no load 14 10 7 4 kHz 20 Push pull force capacity in motion direction 12500 2000 12500 2000 12500 2000 12500 2000 N max Shear load 255 152 84 73 N max Torque on tip 1 5 1...

Page 46: ...3500 30000 3500 30000 3500 N max Shear load 707 420 232 147 147 N max Torque on tip 2 2 2 2 2 Nm max Drive properties Piezo ceramic PICA Power PICA Power PICA Power PICA Power PICA Power Electrical c...

Page 47: ...uency when the operating voltage is 1000 V peak to peak In the case of smaller amplitudes of the operating voltage and or the use of cooling measures higher operating frequencies are possible For furt...

Page 48: ...00 hPa 1 hPa to 10 6 hPa Relative humidity Highest relative humidity 80 for temperatures up to 31 C Decreasing linearly to 50 relative humidity at 40 C Operating temperature P 2x5 xx models 40 C to 80...

Page 49: ...arated by a comma in the drawings Figure 10 P 2x5 1 Sensor only with models with position sensor and or with P 177 50 option 2 Piezo L mm A mm B mm AF P 225 1x 55 39 8 16 13 P 225 2x 68 39 8 16 13 P 2...

Page 50: ...ase of the piezo actuator across from the cable exit 20 mm above the lower edge of the base Position of the purge air outlet In the housing tube of the piezo actuator above the cable exit exact positi...

Page 51: ...Technical Data P 2x5 Piezo Actuator PZ245E Version 1 1 1 47 10 2 5 Flat Tips P 176 F25 and P 176 F35 Figure 12 P 176 F25 1 Plane hardened and polished Figure 13 P 176 F35 1 Plane hardened and polishe...

Page 52: ...ure 14 Vacuum feedthrough LEMO SJG 0B 701 CJA 1173 Designation Description 1 Outer body 2 O ring 12x1 5 3 LEMO device socket J coded EGJ 0B 701 CJA flange side atmosphere 4 LEMO device socket G coded...

Page 53: ...The dimensions of the following vacuum feedthroughs are identical LEMO SWH 0S 304 CLLSV part of the P 892 VA option for SGS LEMO SWH 0S 303 CLLSV part of the P 899 VA option for temperature sensor Fig...

Page 54: ...shield 10 3 2 Connection of the Position Sensor LEMO FFA 0S 304 CLA Connector front view Pin Signal Function 1 Input Supply voltage for strain gauge sensor 2 Output Sensor signal 1 3 Output Sensor sig...

Page 55: ...tional national and local rules and regulations In order to fulfill its responsibility as the product manufacturer Physik Instrumente PI GmbH Co KG undertakes environmentally correct disposal of all o...

Page 56: ......

Page 57: ...f conformity were issued according to the following European statutory requirements Low Voltage Directive EMC Directive RoHS Directive The standards applied for certifying conformity are listed below...

Reviews: