Miscellaneous
L-412
Unit
Toler-
ance
Operating temperature range 5 to 40
°C
Material
Aluminum, black anodized
stainless steel
Overall mass
L-412.03 (52 mm travel range): 6.4
L-412.05 (102 mm travel range): 6.9
L-412.09 (204 mm travel range): 7.9
L-412.13 (305 mm travel range): 8.9
L-412.17 (407 mm travel range): 9.8
L-412.21 (508 mm travel range): 10.8
L-412.25 (610 mm travel range): 11.8
kg
±5 %
Moved mass
1.4
kg
±5 %
MTBF
20000
h
Connector
M23 (motor)
M23 (rotary encoder)
Optional connection for linear encoder
Fitting for purge air hose with outside diame-
ter 4 mm
Funnel-type grease nipple for drive screw lu-
brication
Limit switch connection
M8 8-pin
Purge air system
Operating pressure: 2 to 6 bar (200 to 600
kPa)
Relative humidity: < 70 %
Absolute humidity: < 35 g/m
3
Recommended controllers
ACS modular controller
Connecting cables are not in the scope of delivery and must be ordered separately.
12.2
Maximum Ratings
The L-412.xx9211E0 is designed for the following operating data:
Maximum operating voltage Maximum operating fre-
quency
Maximum peak current, RMS
320 V
–
10.9 A
12.3
Ambient Conditions and Classifications
The following ambient conditions and classifications for the L-412.xx9211E0 must be
observed:
12 TECHNICAL DATA
L412M0016EN
‒
3/14/2019
30
M O T I O N | P O S I T I O N I N G