![PI L-406 Series User Manual Download Page 21](http://html1.mh-extra.com/html/pi/l-406-series/l-406-series_user-manual_1554369021.webp)
5 Installation
L-406 Compact Linear Stage
MP150E
Version: 1.1.0
17
Position of the holes for alignment and mounting of the L-406
(bottom; dark arrows: Mounting holes, long light arrows respectively: Locating
holes 3 mm, short light arrows: Locating holes 4 mm)
L-406.1xxxxx models (example L-
406.10SD00)
L-406.2xxxxx and L-406.4xxxxx models
(example L-406.40SD00)
Requirements
You have read and understood the general notes on installation (p. 15).
You have provided a suitable underlying surface (for the required position and depth of
the holes for accommodating the screws and locating pins, see "Dimensions" (p. 46)):
−
4 or 8 M4 threaded holes are present (depends on the model).
−
If you use locating pins to align the L-406: Two locating holes Ø 3 mm or Ø 4 mm
are provided.
−
The surface flatness is ≤ 10
µm.
−
For applications with large temperature fluctuations: The surface should have the
same thermal expansion properties as the L-406 (e.g., underlying surface made of
aluminum).
You have accounted for the space required to route cables according to regulations and
without bending them.