Requirements
You have read and understood the general notes on installation (p. 7).
You have provided a suitable surface (for the required position and depth of the holes
for accommodating the screws and locating pins, see illustration above).
−
Four M6 threaded holes are present.
−
If you use locating pins to align the positioner: Two Ø 4 mm locating holes are
present.
−
The flatness of the surface is ≤10
µm.
−
For applications with large temperature changes: The surface should have the same
or similar thermal expansion properties as the positioner (e.g., surface made of
aluminum).
You have accounted for the space required to route cables without bending and
according to regulations.
Tools and accessories
Mounting accessories; in the scope of delivery.
−
4 socket head screws, ISO 4762 M6x20
−
2 dowel pins, ISO 8734 - 4 m6 × 12, for use as locating pins
Hex key AF 5 (not included in the scope of delivery)
Mounting the positioner onto a surface
1.
If you use locating pins to align the positioner:
a.
Insert the locating pins into the respective holes in the surface.
b.
Place the positioner on the surface so that the locating pins are inserted into the
corresponding locating holes on the other side.
2.
Otherwise: Align the positioner on the surface so that the corresponding mounting
holes in the positioner and the surface overlap.
3.
Insert the screws into all mounting holes and tighten.
4.
Check that the positioner is affixed firmly to the surface.