Technical Note
H811T0019, valid for H-811.D2 and H-811.S2
Bro, MMa, 9/5/2016
Physik Instrumente (PI) GmbH & Co. KG, Auf der Roemerstrasse 1, 76228 Karlsruhe, Germany
Page 9 / 12
Phone +49 721 4846-0, Fax +49 721 4846-1019, Email
,
www.pi.ws
Technical data specified at 20±3°C.
* The travel ranges of the individual coordinates (X, Y, Z, θX, θY, θZ) are interdependent. The
data for each axis in this table shows its maximum travel, where all other axes are at their zero
positions. If the other linear or rotational coordinates are not zero, the available travel may be
less.
Maximum Ratings
The Hexapod is designed for the following operating data:
Maximum
operating voltage
Maximum operating
frequency (unloaded)
Maximum current
consumption
24 V DC
5 A
Ambient Conditions and Classifications
Degree of pollution:
2
Transport temperature:
–25°C to +85°C
Storage temperature:
0 °C to 70 °C
Humidity:
Maximum relative humidity of 80% at temperatures
of up to 31°C, linearly decreasing until relative
humidity of 50% at 40°C
Degree of protection according to IEC 60529:
IP20
Area of application:
For indoor use only
Maximum altitude:
2000 m