12620-09 and 12620-10 / 2715

 

Mode 

This setting option is available for the following  Cobra4 Sen-
sor-Units: 

 

-

 

Cobra4 Sensor-Unit Timer / Counter (12651-00) 

 

The following operating modes of the Timer / Counter can be 
selected (Fig. 17): 
 

  Measurement of shading times 

  Measurement of runtimes from the start until the 

crossing of the light barrier 

 

Start-stop when crossing the light barrier 

 

Counter mode 

 

Frequency measurement 

 

Wind measurement (with sensor 12124-00) 

 
 
Start 

This setting option is available for the following Cobra4 Sen-
sor-Units: 

 

-

 

Cobra4 Sensor-Unit Timer / Counter (12651-00) 

 

It is used to select the type of start, i.e. a manual start with 

an  automatic  start  with  a  rising  signal 

  or  with  a  falling 

signal 

, or with the external triggers 

 or 

 (Fig. 18). 

 

Gate time 

 

This setting option is available for the following Cobra4 Sen-
sor-Units: 

 

-

 

Cobra4 Sensor-Unit Timer / Counter (12651-00) 

 

 

 
 
 
 

 

 

 

 

 

 

 

 

 

5.4.3

 

Datalogger/Setup (2.1) 

The following changes are possible:

 

 

-

 

Selection of the single-value measurement mode by way 
of  a switch.  This  ensures  that  only  one  value  will  be  re-
corded when a measurement is started. (2.1.1) 

-

 

Selection  of  the  time  interval  between  the  individual 
measurements  and  of  the  unit  of  measurement  (2.1.2 
and 2.1.3). 

-

 

Toggling  between  time  and  the  measurement  value 
number as an X-data set (2.1.4). 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5.4.4

 

Datalogger/Files (2.2) 

In  the  "Datalogger"  menu,  already  existing  measurements 
can be displayed and deleted (Fig. 20). 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fig. 19: Display of the submenu "Datalogger" for the Cobra4 

Mobile-Link 2 

Fig. 18: Display of the submenu "Setup" for the Cobra4 Sensor-

Unit Timer / Counter (12651-00) 

Fig. 20: Display of the submenu "Datalogger > Files" for the 

Cobra4 Mobile-Link 2 

Files 
 
Menu

 

OK

 

Setup 
 
Menu

 

Mode

 

 Timer  

 

Start

 

    

  

   

  Gate time 

      1     s

 

 

 

 

 

 

Menu > Sensor

 

Setup 
 
Menu

 

Single Values

      

 

 

Logging every

 

    50

 

  

 

 

 

Measure Unit

 

    ms 

  

 

 

X-Axis data

 

   Time   

 

 

 

 

 

 

Menu > Datalogger

 

Menu > Datalogger

 

 

 

 

13010101.MLI  

 

 

 

 

13010501.MLI 

 

 

13010502.MLI 

 

 

13010503.MLI

 

 

 

 

13010504.MLI 

 

 

 

Date:

 

01/01/2013 

Sensor:

 

Acceleration 

 

X-axis data

 

   Time     

 

 

 

 

 

 

Summary of Contents for 12620-09

Page 1: ...nsor Setup 1 2 5 4 3 Datalogger Setup 2 1 5 4 4 Datalogger Files 2 2 5 4 5 Zero 3 5 4 6 Calibration 4 5 4 7 Setup Date Time 5 1 5 4 8 Setup Battery status 5 2 5 4 10 Setup Information 5 4 5 4 11 Setup...

Page 2: ...supply unit 3 FUNCTIONAL AND OPERATING ELEMENTS 3 1 Operating elements on the top The Cobra4 Mobile Link 2 is equipped with various elements for the measurement data display operation and status indi...

Page 3: ...nity of the unit After a complete shut down of the unit it must be switched off and on again by way of the ON OFF switch operating ele ment If the unit does not react keep the ON OFF switch pressed fo...

Page 4: ...performed up to three times 5 3 Measurement data recording process A measurement can be started and stopped by pressing the confirmation key The measurement data recording proc ess is indicated by a...

Page 5: ...The file name consists of the date and a running counter YYMMDDxx mli xx 00 99 Ensure that the date and time are set in the Cobra4 Mobile Link This can be checked and if needed changed in the Setup m...

Page 6: ...Unit Conductivity 12632 00 It enables the automatic temperature compensation of a pH or conductivity measuring channel e g T 1 with regard to a temperature input or the manual input of a known temper...

Page 7: ...e following Cobra4 Sen sor Units Cobra4 Sensor Unit Radioactivity 12665 00 It is used to change the counter tube voltage in order to measure the counter tube characteristics Gate time This setting opt...

Page 8: ...imer Counter 12651 00 5 4 3 Datalogger Setup 2 1 The following changes are possible Selection of the single value measurement mode by way of a switch This ensures that only one value will be re corded...

Page 9: ...u item enables the measurement values of the measuring channels to be manually reset to zero To do so the switches of the desired channels are set from off to on by way of the arrow keys Fig 20 You ca...

Page 10: ...played in the header The automatic rotation of the device display can be switched on and off Use the confirmation key in order to confirm a new setting 5 4 10 Setup Information 5 4 Here you can find g...

Page 11: ...es minutes and seconds This menu item can only be used in combination with a Mo bile Link 2 GPS 12620 20 and GPS activated See also chapter 5 4 9 Coordinates will not be displayed unless satellites ha...

Page 12: ...f the battery decreases strongly it is possible to change the battery Please note that damage resulting from a battery change are not covered by the warranty You can send the Mobile Link to the repair...

Page 13: ...Unit Energy 12656 00 Cobra4 Sensor Unit Forceplate 12661 00 Cobra4 Sensor Unit Radioactivity 12665 00 Cobra4 Sensor Unit Sound Level 12669 00 Cobra4 Sensor Unit Weather air pressure humidity temperatu...

Reviews: