10.3.11
Release Notes
The following section contains information about deviations to the
description in this manual. Revisions to previous manuals are also
listed.
Caution:
This manual exclusively describes the board revision 4132.0
Revision:
PCB# 4132.0
•
/RESTI signal monitoring LED D33 without function. Current
limiting resistor R122 is removed. With installed R122, /RSTI
signal don’t reach signal low level.
•
CF-Card socket X8 pin 7 is disconnected from /FB_CS1 and wired
to the phyCORE connector X1A6 signal XPLD3_1.
•
Power Connector X10: Pins 2 and 3 have to short circuit to connect
the system ground to the external power supply line.